2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-21 19:53:59 +08:00
linux-next/Documentation/hwmon/lm73.rst
Alexander A. Klimov ad736c1a4d hwmon: Replace HTTP links with HTTPS ones
Rationale:
Reduces attack surface on kernel devs opening the links for MITM
as HTTPS traffic is much harder to manipulate.

Deterministic algorithm:
For each file:
  If not .svg:
    For each line:
      If doesn't contain `\bxmlns\b`:
        For each link, `\bhttp://[^# \t\r\n]*(?:\w|/)`:
	  If neither `\bgnu\.org/license`, nor `\bmozilla\.org/MPL\b`:
            If both the HTTP and HTTPS versions
            return 200 OK and serve the same content:
              Replace HTTP with HTTPS.

Signed-off-by: Alexander A. Klimov <grandmaster@al2klimov.de>
Link: https://lore.kernel.org/r/20200719175512.60745-1-grandmaster@al2klimov.de
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-07-24 07:44:57 -07:00

99 lines
2.7 KiB
ReStructuredText

Kernel driver lm73
==================
Supported chips:
* Texas Instruments LM73
Prefix: 'lm73'
Addresses scanned: I2C 0x48, 0x49, 0x4a, 0x4c, 0x4d, and 0x4e
Datasheet: Publicly available at the Texas Instruments website
https://www.ti.com/product/lm73
Author: Guillaume Ligneul <guillaume.ligneul@gmail.com>
Documentation: Chris Verges <kg4ysn@gmail.com>
Description
-----------
The LM73 is a digital temperature sensor. All temperature values are
given in degrees Celsius.
Measurement Resolution Support
------------------------------
The LM73 supports four resolutions, defined in terms of degrees C per
LSB: 0.25, 0.125, 0.0625, and 0.3125. Changing the resolution mode
affects the conversion time of the LM73's analog-to-digital converter.
From userspace, the desired resolution can be specified as a function of
conversion time via the 'update_interval' sysfs attribute for the
device. This attribute will normalize ranges of input values to the
maximum times defined for the resolution in the datasheet.
============= ============= ============
Resolution Conv. Time Input Range
(C/LSB) (msec) (msec)
============= ============= ============
0.25 14 0..14
0.125 28 15..28
0.0625 56 29..56
0.03125 112 57..infinity
============= ============= ============
The following examples show how the 'update_interval' attribute can be
used to change the conversion time::
$ echo 0 > update_interval
$ cat update_interval
14
$ cat temp1_input
24250
$ echo 22 > update_interval
$ cat update_interval
28
$ cat temp1_input
24125
$ echo 56 > update_interval
$ cat update_interval
56
$ cat temp1_input
24062
$ echo 85 > update_interval
$ cat update_interval
112
$ cat temp1_input
24031
As shown here, the lm73 driver automatically adjusts any user input for
'update_interval' via a step function. Reading back the
'update_interval' value after a write operation will confirm the
conversion time actively in use.
Mathematically, the resolution can be derived from the conversion time
via the following function:
g(x) = 0.250 * [log(x/14) / log(2)]
where 'x' is the output from 'update_interval' and 'g(x)' is the
resolution in degrees C per LSB.
Alarm Support
-------------
The LM73 features a simple over-temperature alarm mechanism. This
feature is exposed via the sysfs attributes.
The attributes 'temp1_max_alarm' and 'temp1_min_alarm' are flags
provided by the LM73 that indicate whether the measured temperature has
passed the 'temp1_max' and 'temp1_min' thresholds, respectively. These
values _must_ be read to clear the registers on the LM73.