mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-24 13:13:57 +08:00
9e40127526
Already existing property flags are filled wrong for properties created from initial FDT. This could cause problems if this DYNAMIC device-tree functions are used later, i.e. properties are attached/detached/replaced. Simply dumping flags from the running system show, that some initial static (not allocated via kzmalloc()) nodes are marked as dynamic. I putted some debug extensions to property_proc_show(..) : .. + if (OF_IS_DYNAMIC(pp)) + pr_err("DEBUG: xxx : OF_IS_DYNAMIC\n"); + if (OF_IS_DETACHED(pp)) + pr_err("DEBUG: xxx : OF_IS_DETACHED\n"); when you operate on the nodes (e.g.: ~$ cat /proc/device-tree/*some_node*) you will see that those flags are filled wrong, basically in most cases it will dump a DYNAMIC or DETACHED status, which is in not true. (BTW. this OF_IS_DETACHED is a own define for debug purposes which which just make a test_bit(OF_DETACHED, &x->_flags) If nodes are dynamic kernel is allowed to kfree() them. But it will crash attempting to do so on the nodes from FDT -- they are not allocated via kzmalloc(). Signed-off-by: Wladislav Wiebe <wladislav.kw@gmail.com> Acked-by: Alexander Sverdlin <alexander.sverdlin@nsn.com> Cc: stable@vger.kernel.org Signed-off-by: Rob Herring <rob.herring@calxeda.com> |
||
---|---|---|
.. | ||