2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-27 14:43:58 +08:00
linux-next/arch/mips/netlogic/Kconfig
Christoph Hellwig 86596f0a28 scatterlist: move the NEED_SG_DMA_LENGTH config symbol to lib/Kconfig
This way we have one central definition of it, and user can select it as
needed.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Anshuman Khandual <khandual@linux.vnet.ibm.com>
2018-05-09 06:55:59 +02:00

87 lines
2.2 KiB
Plaintext

# SPDX-License-Identifier: GPL-2.0
if NLM_XLP_BOARD || NLM_XLR_BOARD
if NLM_XLP_BOARD
config DT_XLP_EVP
bool "Built-in device tree for XLP EVP boards"
default y
select BUILTIN_DTB
help
Add an FDT blob for XLP EVP boards into the kernel.
This DTB will be used if the firmware does not pass in a DTB
pointer to the kernel. The corresponding DTS file is at
arch/mips/netlogic/dts/xlp_evp.dts
config DT_XLP_SVP
bool "Built-in device tree for XLP SVP boards"
default y
select BUILTIN_DTB
help
Add an FDT blob for XLP VP boards into the kernel.
This DTB will be used if the firmware does not pass in a DTB
pointer to the kernel. The corresponding DTS file is at
arch/mips/netlogic/dts/xlp_svp.dts
config DT_XLP_FVP
bool "Built-in device tree for XLP FVP boards"
default y
select BUILTIN_DTB
help
Add an FDT blob for XLP FVP board into the kernel.
This DTB will be used if the firmware does not pass in a DTB
pointer to the kernel. The corresponding DTS file is at
arch/mips/netlogic/dts/xlp_fvp.dts
config DT_XLP_GVP
bool "Built-in device tree for XLP GVP boards"
default y
select BUILTIN_DTB
help
Add an FDT blob for XLP GVP board into the kernel.
This DTB will be used if the firmware does not pass in a DTB
pointer to the kernel. The corresponding DTS file is at
arch/mips/netlogic/dts/xlp_gvp.dts
config DT_XLP_RVP
bool "Built-in device tree for XLP RVP boards"
default y
help
Add an FDT blob for XLP RVP board into the kernel.
This DTB will be used if the firmware does not pass in a DTB
pointer to the kernel. The corresponding DTS file is at
arch/mips/netlogic/dts/xlp_rvp.dts
config NLM_MULTINODE
bool "Support for multi-chip boards"
depends on NLM_XLP_BOARD
default n
help
Add support for boards with 2 or 4 XLPs connected over ICI.
if NLM_MULTINODE
choice
prompt "Number of XLPs on the board"
default NLM_MULTINODE_2
help
In the multi-node case, specify the number of SoCs on the board.
config NLM_MULTINODE_2
bool "Dual-XLP board"
help
Support boards with upto two XLPs connected over ICI.
config NLM_MULTINODE_4
bool "Quad-XLP board"
help
Support boards with upto four XLPs connected over ICI.
endchoice
endif
endif
config NLM_COMMON
bool
endif