* Clock bindings for Freescale i.MX31
|
|
|
|
Required properties:
|
|
- compatible: Should be "fsl,imx31-ccm"
|
|
- reg: Address and length of the register set
|
|
- interrupts: Should contain CCM interrupt
|
|
- #clock-cells: Should be <1>
|
|
|
|
The clock consumer should specify the desired clock by having the clock
|
|
ID in its "clocks" phandle cell. The following is a full list of i.MX31
|
|
clocks and IDs.
|
|
|
|
Clock ID
|
|
-----------------------
|
|
dummy 0
|
|
ckih 1
|
|
ckil 2
|
|
mpll 3
|
|
spll 4
|
|
upll 5
|
|
mcu_main 6
|
|
hsp 7
|
|
ahb 8
|
|
nfc 9
|
|
ipg 10
|
|
per_div 11
|
|
per 12
|
|
csi_sel 13
|
|
fir_sel 14
|
|
csi_div 15
|
|
usb_div_pre 16
|
|
usb_div_post 17
|
|
fir_div_pre 18
|
|
fir_div_post 19
|
|
sdhc1_gate 20
|
|
sdhc2_gate 21
|
|
gpt_gate 22
|
|
epit1_gate 23
|
|
epit2_gate 24
|
|
iim_gate 25
|
|
ata_gate 26
|
|
sdma_gate 27
|
|
cspi3_gate 28
|
|
rng_gate 29
|
|
uart1_gate 30
|
|
uart2_gate 31
|
|
ssi1_gate 32
|
|
i2c1_gate 33
|
|
i2c2_gate 34
|
|
i2c3_gate 35
|
|
hantro_gate 36
|
|
mstick1_gate 37
|
|
mstick2_gate 38
|
|
csi_gate 39
|
|
rtc_gate 40
|
|
wdog_gate 41
|
|
pwm_gate 42
|
|
sim_gate 43
|
|
ect_gate 44
|
|
usb_gate 45
|
|
kpp_gate 46
|
|
ipu_gate 47
|
|
uart3_gate 48
|
|
uart4_gate 49
|
|
uart5_gate 50
|
|
owire_gate 51
|
|
ssi2_gate 52
|
|
cspi1_gate 53
|
|
cspi2_gate 54
|
|
gacc_gate 55
|
|
emi_gate 56
|
|
rtic_gate 57
|
|
firi_gate 58
|
|
|
|
Examples:
|
|
|
|
clks: ccm@53f80000{
|
|
compatible = "fsl,imx31-ccm";
|
|
reg = <0x53f80000 0x4000>;
|
|
interrupts = <0 31 0x04 0 53 0x04>;
|
|
#clock-cells = <1>;
|
|
};
|
|
|
|
uart1: serial@43f90000 {
|
|
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
|
reg = <0x43f90000 0x4000>;
|
|
interrupts = <45>;
|
|
clocks = <&clks 10>, <&clks 30>;
|
|
clock-names = "ipg", "per";
|
|
status = "disabled";
|
|
};
|