When run ethtool cmd(ethtool -t ethx) again and again for a long time, it will be probabilistically fail. The PHYs' registers may be on different pages, so it must be switch to the right page before setting PHYs' registers. And __lb_up() calls phy_start() to startup the PHYs device, but this function may change Copper Control Register(Page 0, Register 0) to an other value. It would cause phy loopback test fail. if we remove phy_start(), we have to remove the relative phy_stop(), phy_disconnect() when doing phy loopback to keep the phy stay in right status. Reported-by: hejun <hjat2005@huawei.com> Signed-off-by: Kejian Yan <yankejian@huawei.com> Signed-off-by: Yisen Zhuang <Yisen.Zhuang@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net> |
||
---|---|---|
.. | ||