The sysfs layout is created by CM incorrectly presented RDMA devices with
InfiniBand link layer. Layout of such devices represents device tree of
connections. By moving CM statistics to be under relevant port of IB
device, we will fix the following issues:
* Symlink name - It used device name instead of specific identifier.
* Target location - It was supposed to point to PCI-ID/infiniband_cm/
instead of PCI-ID/infiniband/
* Target name - It created extra device file under already existing
device folder, e.g. mlx5_0/mlx5_0
* Crash during boot with RDMA persistent naming patches.
sysfs: cannot create duplicate filename '/class/infiniband_cm/mlx5_0'
CPU: 29 PID: 433 Comm: modprobe Not tainted 5.0.0-rc5+ #178
Call Trace:
dump_stack+0xcc/0x180
sysfs_warn_dup.cold.3+0x17/0x2d
sysfs_do_create_link_sd.isra.2+0xd0/0xf0
device_add+0x7cb/0x1450
device_create_groups_vargs+0x1ae/0x220
device_create+0x93/0xc0
cm_add_one+0x38f/0xf60 [ib_cm]
add_client_context+0x167/0x210 [ib_core]
enable_device_and_get+0x230/0x3f0 [ib_core]
ib_register_device+0x823/0xbf0 [ib_core]
__mlx5_ib_add+0x45/0x150 [mlx5_ib]
mlx5_ib_add+0x1b3/0x5e0 [mlx5_ib]
mlx5_add_device+0x130/0x3a0 [mlx5_core]
mlx5_register_interface+0x1a9/0x270 [mlx5_core]
do_one_initcall+0x14f/0x5de
do_init_module+0x247/0x7c0
load_module+0x4c2f/0x60d0
entry_SYSCALL_64_after_hwframe+0x49/0xbe
After this change:
[leonro@server ~]$ ls -al /sys/class/infiniband/ibp0s12f0/ports/1/
drwxr-xr-x 2 root root 0 Mar 11 11:17 cm_rx_duplicates
drwxr-xr-x 2 root root 0 Mar 11 11:17 cm_rx_msgs
drwxr-xr-x 2 root root 0 Mar 11 11:17 cm_tx_msgs
drwxr-xr-x 2 root root 0 Mar 11 11:17 cm_tx_retries
Fixes: 110cf374a8 ("infiniband: make cm_device use a struct device and not a kobject.")
Signed-off-by: Leon Romanovsky <leonro@mellanox.com>