Nicolin Chen a9e9dd9c6d hwmon: (ina3221) Read channel input source info from DT
An ina3221 chip has three input ports. Each port is used
to measure the voltage and current of its input source.

The DT binding now has defined bindings for their input
sources, so the driver should read these information and
handle accordingly.

This patch adds a new structure of input source specific
information including input source label, shunt resistor
value and its connection status. It exposes these labels
via in[123]_label sysfs nodes upon available, and also
disables those channels where there are no input source
being connected. Meanwhile, it also adds in[123]_enable
sysfs nodes for users to get control of three channels,
and returns -ENODATA code for any sensor read according
to hwmon ABI.

Signed-off-by: Nicolin Chen <nicoleotsuka@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-10-10 20:37:13 -07:00

38 lines
1.5 KiB
Plaintext

Kernel driver ina3221
=====================
Supported chips:
* Texas Instruments INA3221
Prefix: 'ina3221'
Addresses: I2C 0x40 - 0x43
Datasheet: Publicly available at the Texas Instruments website
http://www.ti.com/
Author: Andrew F. Davis <afd@ti.com>
Description
-----------
The Texas Instruments INA3221 monitors voltage, current, and power on the high
side of up to three D.C. power supplies. The INA3221 monitors both shunt drop
and supply voltage, with programmable conversion times and averaging, current
and power are calculated host-side from these.
Sysfs entries
-------------
in[123]_label Voltage channel labels
in[123]_enable Voltage channel enable controls
in[123]_input Bus voltage(mV) channels
curr[123]_input Current(mA) measurement channels
shunt[123]_resistor Shunt resistance(uOhm) channels
curr[123]_crit Critical alert current(mA) setting, activates the
corresponding alarm when the respective current
is above this value
curr[123]_crit_alarm Critical alert current limit exceeded
curr[123]_max Warning alert current(mA) setting, activates the
corresponding alarm when the respective current
average is above this value.
curr[123]_max_alarm Warning alert current limit exceeded
in[456]_input Shunt voltage(uV) for channels 1, 2, and 3 respectively