2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-23 04:34:11 +08:00
linux-next/Documentation/devicetree/bindings/interrupt-controller/marvell,icu.txt
Thomas Petazzoni f39a29bb5c dt-bindings/interrupt-controller: Add DT binding for the Marvell ICU
This commit adds the Device Tree binding documentation for the Marvell
ICU interrupt controller, which collects wired interrupts from the
devices located into the CP110 hardware block of Marvell Armada 7K/8K,
and converts them into SPI interrupts in the GIC located in the AP
hardware block, using the GICP extension.

Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
2017-06-23 09:14:43 +01:00

52 lines
1.5 KiB
Plaintext

Marvell ICU Interrupt Controller
--------------------------------
The Marvell ICU (Interrupt Consolidation Unit) controller is
responsible for collecting all wired-interrupt sources in the CP and
communicating them to the GIC in the AP, the unit translates interrupt
requests on input wires to MSG memory mapped transactions to the GIC.
Required properties:
- compatible: Should be "marvell,cp110-icu"
- reg: Should contain ICU registers location and length.
- #interrupt-cells: Specifies the number of cells needed to encode an
interrupt source. The value shall be 3.
The 1st cell is the group type of the ICU interrupt. Possible group
types are:
ICU_GRP_NSR (0x0) : Shared peripheral interrupt, non-secure
ICU_GRP_SR (0x1) : Shared peripheral interrupt, secure
ICU_GRP_SEI (0x4) : System error interrupt
ICU_GRP_REI (0x5) : RAM error interrupt
The 2nd cell is the index of the interrupt in the ICU unit.
The 3rd cell is the type of the interrupt. See arm,gic.txt for
details.
- interrupt-controller: Identifies the node as an interrupt
controller.
- msi-parent: Should point to the GICP controller, the GIC extension
that allows to trigger interrupts using MSG memory mapped
transactions.
Example:
icu: interrupt-controller@1e0000 {
compatible = "marvell,cp110-icu";
reg = <0x1e0000 0x10>;
#interrupt-cells = <3>;
interrupt-controller;
msi-parent = <&gicp>;
};
usb3h0: usb3@500000 {
interrupt-parent = <&icu>;
interrupts = <ICU_GRP_NSR 106 IRQ_TYPE_LEVEL_HIGH>;
};