Correct spelling problems for Documentation/networking/ as reported by codespell. Signed-off-by: Randy Dunlap <rdunlap@infradead.org> Cc: Jonathan Corbet <corbet@lwn.net> Cc: linux-doc@vger.kernel.org Cc: Jiri Pirko <jiri@nvidia.com> Cc: "David S. Miller" <davem@davemloft.net> Cc: Eric Dumazet <edumazet@google.com> Cc: Jakub Kicinski <kuba@kernel.org> Cc: Paolo Abeni <pabeni@redhat.com> Cc: netdev@vger.kernel.org Link: https://lore.kernel.org/r/20230129231053.20863-5-rdunlap@infradead.org Signed-off-by: Paolo Abeni <pabeni@redhat.com>
185 lines
7.2 KiB
ReStructuredText
185 lines
7.2 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0
|
|
|
|
============
|
|
NET_FAILOVER
|
|
============
|
|
|
|
Overview
|
|
========
|
|
|
|
The net_failover driver provides an automated failover mechanism via APIs
|
|
to create and destroy a failover master netdev and manages a primary and
|
|
standby slave netdevs that get registered via the generic failover
|
|
infrastructure.
|
|
|
|
The failover netdev acts a master device and controls 2 slave devices. The
|
|
original paravirtual interface is registered as 'standby' slave netdev and
|
|
a passthru/vf device with the same MAC gets registered as 'primary' slave
|
|
netdev. Both 'standby' and 'failover' netdevs are associated with the same
|
|
'pci' device. The user accesses the network interface via 'failover' netdev.
|
|
The 'failover' netdev chooses 'primary' netdev as default for transmits when
|
|
it is available with link up and running.
|
|
|
|
This can be used by paravirtual drivers to enable an alternate low latency
|
|
datapath. It also enables hypervisor controlled live migration of a VM with
|
|
direct attached VF by failing over to the paravirtual datapath when the VF
|
|
is unplugged.
|
|
|
|
virtio-net accelerated datapath: STANDBY mode
|
|
=============================================
|
|
|
|
net_failover enables hypervisor controlled accelerated datapath to virtio-net
|
|
enabled VMs in a transparent manner with no/minimal guest userspace changes.
|
|
|
|
To support this, the hypervisor needs to enable VIRTIO_NET_F_STANDBY
|
|
feature on the virtio-net interface and assign the same MAC address to both
|
|
virtio-net and VF interfaces.
|
|
|
|
Here is an example libvirt XML snippet that shows such configuration:
|
|
::
|
|
|
|
<interface type='network'>
|
|
<mac address='52:54:00:00:12:53'/>
|
|
<source network='enp66s0f0_br'/>
|
|
<target dev='tap01'/>
|
|
<model type='virtio'/>
|
|
<driver name='vhost' queues='4'/>
|
|
<link state='down'/>
|
|
<teaming type='persistent'/>
|
|
<alias name='ua-backup0'/>
|
|
</interface>
|
|
<interface type='hostdev' managed='yes'>
|
|
<mac address='52:54:00:00:12:53'/>
|
|
<source>
|
|
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
|
</source>
|
|
<teaming type='transient' persistent='ua-backup0'/>
|
|
</interface>
|
|
|
|
In this configuration, the first device definition is for the virtio-net
|
|
interface and this acts as the 'persistent' device indicating that this
|
|
interface will always be plugged in. This is specified by the 'teaming' tag with
|
|
required attribute type having value 'persistent'. The link state for the
|
|
virtio-net device is set to 'down' to ensure that the 'failover' netdev prefers
|
|
the VF passthrough device for normal communication. The virtio-net device will
|
|
be brought UP during live migration to allow uninterrupted communication.
|
|
|
|
The second device definition is for the VF passthrough interface. Here the
|
|
'teaming' tag is provided with type 'transient' indicating that this device may
|
|
periodically be unplugged. A second attribute - 'persistent' is provided and
|
|
points to the alias name declared for the virtio-net device.
|
|
|
|
Booting a VM with the above configuration will result in the following 3
|
|
interfaces created in the VM:
|
|
::
|
|
|
|
4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
|
|
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
|
inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10
|
|
valid_lft 42482sec preferred_lft 42482sec
|
|
inet6 fe80::97d8:db2:8c10:b6d6/64 scope link
|
|
valid_lft forever preferred_lft forever
|
|
5: ens10nsby: <BROADCAST,MULTICAST> mtu 1500 qdisc fq_codel master ens10 state DOWN group default qlen 1000
|
|
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
|
7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000
|
|
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
|
|
|
Here, ens10 is the 'failover' master interface, ens10nsby is the slave 'standby'
|
|
virtio-net interface, and ens11 is the slave 'primary' VF passthrough interface.
|
|
|
|
One point to note here is that some user space network configuration daemons
|
|
like systemd-networkd, ifupdown, etc, do not understand the 'net_failover'
|
|
device; and on the first boot, the VM might end up with both 'failover' device
|
|
and VF acquiring IP addresses (either same or different) from the DHCP server.
|
|
This will result in lack of connectivity to the VM. So some tweaks might be
|
|
needed to these network configuration daemons to make sure that an IP is
|
|
received only on the 'failover' device.
|
|
|
|
Below is the patch snippet used with 'cloud-ifupdown-helper' script found on
|
|
Debian cloud images:
|
|
|
|
::
|
|
@@ -27,6 +27,8 @@ do_setup() {
|
|
local working="$cfgdir/.$INTERFACE"
|
|
local final="$cfgdir/$INTERFACE"
|
|
|
|
+ if [ -d "/sys/class/net/${INTERFACE}/master" ]; then exit 0; fi
|
|
+
|
|
if ifup --no-act "$INTERFACE" > /dev/null 2>&1; then
|
|
# interface is already known to ifupdown, no need to generate cfg
|
|
log "Skipping configuration generation for $INTERFACE"
|
|
|
|
|
|
Live Migration of a VM with SR-IOV VF & virtio-net in STANDBY mode
|
|
==================================================================
|
|
|
|
net_failover also enables hypervisor controlled live migration to be supported
|
|
with VMs that have direct attached SR-IOV VF devices by automatic failover to
|
|
the paravirtual datapath when the VF is unplugged.
|
|
|
|
Here is a sample script that shows the steps to initiate live migration from
|
|
the source hypervisor. Note: It is assumed that the VM is connected to a
|
|
software bridge 'br0' which has a single VF attached to it along with the vnet
|
|
device to the VM. This is not the VF that was passthrough'd to the VM (seen in
|
|
the vf.xml file).
|
|
::
|
|
|
|
# cat vf.xml
|
|
<interface type='hostdev' managed='yes'>
|
|
<mac address='52:54:00:00:12:53'/>
|
|
<source>
|
|
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
|
</source>
|
|
<teaming type='transient' persistent='ua-backup0'/>
|
|
</interface>
|
|
|
|
# Source Hypervisor migrate.sh
|
|
#!/bin/bash
|
|
|
|
DOMAIN=vm-01
|
|
PF=ens6np0
|
|
VF=ens6v1 # VF attached to the bridge.
|
|
VF_NUM=1
|
|
TAP_IF=vmtap01 # virtio-net interface in the VM.
|
|
VF_XML=vf.xml
|
|
|
|
MAC=52:54:00:00:12:53
|
|
ZERO_MAC=00:00:00:00:00:00
|
|
|
|
# Set the virtio-net interface up.
|
|
virsh domif-setlink $DOMAIN $TAP_IF up
|
|
|
|
# Remove the VF that was passthrough'd to the VM.
|
|
virsh detach-device --live --config $DOMAIN $VF_XML
|
|
|
|
ip link set $PF vf $VF_NUM mac $ZERO_MAC
|
|
|
|
# Add FDB entry for traffic to continue going to the VM via
|
|
# the VF -> br0 -> vnet interface path.
|
|
bridge fdb add $MAC dev $VF
|
|
bridge fdb add $MAC dev $TAP_IF master
|
|
|
|
# Migrate the VM
|
|
virsh migrate --live --persistent $DOMAIN qemu+ssh://$REMOTE_HOST/system
|
|
|
|
# Clean up FDB entries after migration completes.
|
|
bridge fdb del $MAC dev $VF
|
|
bridge fdb del $MAC dev $TAP_IF master
|
|
|
|
On the destination hypervisor, a shared bridge 'br0' is created before migration
|
|
starts, and a VF from the destination PF is added to the bridge. Similarly an
|
|
appropriate FDB entry is added.
|
|
|
|
The following script is executed on the destination hypervisor once migration
|
|
completes, and it reattaches the VF to the VM and brings down the virtio-net
|
|
interface.
|
|
|
|
::
|
|
# reattach-vf.sh
|
|
#!/bin/bash
|
|
|
|
bridge fdb del 52:54:00:00:12:53 dev ens36v0
|
|
bridge fdb del 52:54:00:00:12:53 dev vmtap01 master
|
|
virsh attach-device --config --live vm01 vf.xml
|
|
virsh domif-setlink vm01 vmtap01 down
|