2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-29 07:34:06 +08:00
linux-next/drivers/hwmon/pmbus/Kconfig
Guenter Roeck 58615a94f6 hwmon: (pmbus/lm25066) Add support for LM25056
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2013-04-07 21:16:41 -07:00

125 lines
3.5 KiB
Plaintext

#
# PMBus chip drivers configuration
#
menuconfig PMBUS
tristate "PMBus support"
depends on I2C
default n
help
Say yes here if you want to enable PMBus support.
This driver can also be built as a module. If so, the module will
be called pmbus_core.
if PMBUS
config SENSORS_PMBUS
tristate "Generic PMBus devices"
default y
help
If you say yes here you get hardware monitoring support for generic
PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, UDT020, TPS40400,
and TPS40422.
This driver can also be built as a module. If so, the module will
be called pmbus.
config SENSORS_ADM1275
tristate "Analog Devices ADM1275 and compatibles"
default n
help
If you say yes here you get hardware monitoring support for Analog
Devices ADM1075, ADM1275, and ADM1276 Hot-Swap Controller and Digital
Power Monitors.
This driver can also be built as a module. If so, the module will
be called adm1275.
config SENSORS_LM25066
tristate "National Semiconductor LM25066 and compatibles"
default n
help
If you say yes here you get hardware monitoring support for National
Semiconductor LM25056, LM25066, LM5064, and LM5066.
This driver can also be built as a module. If so, the module will
be called lm25066.
config SENSORS_LTC2978
tristate "Linear Technologies LTC2974, LTC2978, LTC3880, and LTC3883"
default n
help
If you say yes here you get hardware monitoring support for Linear
Technology LTC2974, LTC2978, LTC3880, and LTC3883.
This driver can also be built as a module. If so, the module will
be called ltc2978.
config SENSORS_MAX16064
tristate "Maxim MAX16064"
default n
help
If you say yes here you get hardware monitoring support for Maxim
MAX16064.
This driver can also be built as a module. If so, the module will
be called max16064.
config SENSORS_MAX34440
tristate "Maxim MAX34440 and compatibles"
default n
help
If you say yes here you get hardware monitoring support for Maxim
MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461.
This driver can also be built as a module. If so, the module will
be called max34440.
config SENSORS_MAX8688
tristate "Maxim MAX8688"
default n
help
If you say yes here you get hardware monitoring support for Maxim
MAX8688.
This driver can also be built as a module. If so, the module will
be called max8688.
config SENSORS_UCD9000
tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
default n
help
If you say yes here you get hardware monitoring support for TI
UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
Controllers.
This driver can also be built as a module. If so, the module will
be called ucd9000.
config SENSORS_UCD9200
tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
default n
help
If you say yes here you get hardware monitoring support for TI
UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
Digital PWM System Controllers.
This driver can also be built as a module. If so, the module will
be called ucd9200.
config SENSORS_ZL6100
tristate "Intersil ZL6100 and compatibles"
default n
help
If you say yes here you get hardware monitoring support for Intersil
ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
This driver can also be built as a module. If so, the module will
be called zl6100.
endif # PMBUS