2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-25 21:54:06 +08:00
linux-next/Documentation/devicetree/bindings/clock/renesas,r8a7778-cpg-clocks.txt
Geert Uytterhoeven 8bc964aa25 clk: shmobile: r8a7778: Add CPG/MSTP Clock Domain support
Add Clock Domain support to the R-Car M1A Clock Pulse Generator (CPG)
driver using the generic PM Domain.  This allows to power-manage the
module clocks of SoC devices that are part of the CPG/MSTP Clock Domain
using Runtime PM, or for system suspend/resume.

SoC devices that are part of the CPG/MSTP Clock Domain and can be
power-managed through an MSTP clock should be tagged in DT with a proper
"power-domains" property.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Stephen Boyd <sboyd@codeaurora.org>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
2015-08-12 10:31:27 +09:00

49 lines
1.4 KiB
Plaintext

* Renesas R8A7778 Clock Pulse Generator (CPG)
The CPG generates core clocks for the R8A7778. It includes two PLLs and
several fixed ratio dividers.
The CPG also provides a Clock Domain for SoC devices, in combination with the
CPG Module Stop (MSTP) Clocks.
Required Properties:
- compatible: Must be "renesas,r8a7778-cpg-clocks"
- reg: Base address and length of the memory resource used by the CPG
- #clock-cells: Must be 1
- clock-output-names: The names of the clocks. Supported clocks are
"plla", "pllb", "b", "out", "p", "s", and "s1".
- #power-domain-cells: Must be 0
SoC devices that are part of the CPG/MSTP Clock Domain and can be power-managed
through an MSTP clock should refer to the CPG device node in their
"power-domains" property, as documented by the generic PM domain bindings in
Documentation/devicetree/bindings/power/power_domain.txt.
Examples
--------
- CPG device node:
cpg_clocks: cpg_clocks@ffc80000 {
compatible = "renesas,r8a7778-cpg-clocks";
reg = <0xffc80000 0x80>;
#clock-cells = <1>;
clocks = <&extal_clk>;
clock-output-names = "plla", "pllb", "b",
"out", "p", "s", "s1";
#power-domain-cells = <0>;
};
- CPG/MSTP Clock Domain member device node:
sdhi0: sd@ffe4c000 {
compatible = "renesas,sdhi-r8a7778";
reg = <0xffe4c000 0x100>;
interrupts = <0 87 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&mstp3_clks R8A7778_CLK_SDHI0>;
power-domains = <&cpg_clocks>;
status = "disabled";
};