2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-29 15:43:59 +08:00
linux-next/Documentation/leds/leds-mlxcpld.rst
Mauro Carvalho Chehab 8dab91970a docs: leds: convert to ReST
Rename the leds documentation files to ReST, add an
index for them and adjust in order to produce a nice html
output via the Sphinx build system.

At its new index.rst, let's add a :orphan: while this is not linked to
the main index.rst file, in order to avoid build warnings.

Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>
2019-06-28 20:57:31 +02:00

119 lines
2.4 KiB
ReStructuredText

=======================================
Kernel driver for Mellanox systems LEDs
=======================================
Provide system LED support for the nex Mellanox systems:
"msx6710", "msx6720", "msb7700", "msn2700", "msx1410",
"msn2410", "msb7800", "msn2740", "msn2100".
Description
-----------
Driver provides the following LEDs for the systems "msx6710", "msx6720",
"msb7700", "msn2700", "msx1410", "msn2410", "msb7800", "msn2740":
- mlxcpld:fan1:green
- mlxcpld:fan1:red
- mlxcpld:fan2:green
- mlxcpld:fan2:red
- mlxcpld:fan3:green
- mlxcpld:fan3:red
- mlxcpld:fan4:green
- mlxcpld:fan4:red
- mlxcpld:psu:green
- mlxcpld:psu:red
- mlxcpld:status:green
- mlxcpld:status:red
"status"
- CPLD reg offset: 0x20
- Bits [3:0]
"psu"
- CPLD reg offset: 0x20
- Bits [7:4]
"fan1"
- CPLD reg offset: 0x21
- Bits [3:0]
"fan2"
- CPLD reg offset: 0x21
- Bits [7:4]
"fan3"
- CPLD reg offset: 0x22
- Bits [3:0]
"fan4"
- CPLD reg offset: 0x22
- Bits [7:4]
Color mask for all the above LEDs:
[bit3,bit2,bit1,bit0] or
[bit7,bit6,bit5,bit4]:
- [0,0,0,0] = LED OFF
- [0,1,0,1] = Red static ON
- [1,1,0,1] = Green static ON
- [0,1,1,0] = Red blink 3Hz
- [1,1,1,0] = Green blink 3Hz
- [0,1,1,1] = Red blink 6Hz
- [1,1,1,1] = Green blink 6Hz
Driver provides the following LEDs for the system "msn2100":
- mlxcpld:fan:green
- mlxcpld:fan:red
- mlxcpld:psu1:green
- mlxcpld:psu1:red
- mlxcpld:psu2:green
- mlxcpld:psu2:red
- mlxcpld:status:green
- mlxcpld:status:red
- mlxcpld:uid:blue
"status"
- CPLD reg offset: 0x20
- Bits [3:0]
"fan"
- CPLD reg offset: 0x21
- Bits [3:0]
"psu1"
- CPLD reg offset: 0x23
- Bits [3:0]
"psu2"
- CPLD reg offset: 0x23
- Bits [7:4]
"uid"
- CPLD reg offset: 0x24
- Bits [3:0]
Color mask for all the above LEDs, excepted uid:
[bit3,bit2,bit1,bit0] or
[bit7,bit6,bit5,bit4]:
- [0,0,0,0] = LED OFF
- [0,1,0,1] = Red static ON
- [1,1,0,1] = Green static ON
- [0,1,1,0] = Red blink 3Hz
- [1,1,1,0] = Green blink 3Hz
- [0,1,1,1] = Red blink 6Hz
- [1,1,1,1] = Green blink 6Hz
Color mask for uid LED:
[bit3,bit2,bit1,bit0]:
- [0,0,0,0] = LED OFF
- [1,1,0,1] = Blue static ON
- [1,1,1,0] = Blue blink 3Hz
- [1,1,1,1] = Blue blink 6Hz
Driver supports HW blinking at 3Hz and 6Hz frequency (50% duty cycle).
For 3Hz duty cylce is about 167 msec, for 6Hz is about 83 msec.