2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2025-01-06 12:44:14 +08:00
linux-next/arch/arm64/kvm/pmu.c
Andrew Murray 3d91befbb3 arm64: KVM: Enable !VHE support for :G/:H perf event modifiers
Enable/disable event counters as appropriate when entering and exiting
the guest to enable support for guest or host only event counting.

For both VHE and non-VHE we switch the counters between host/guest at
EL2.

The PMU may be on when we change which counters are enabled however
we avoid adding an isb as we instead rely on existing context
synchronisation events: the eret to enter the guest (__guest_enter)
and eret in kvm_call_hyp for __kvm_vcpu_run_nvhe on returning.

Signed-off-by: Andrew Murray <andrew.murray@arm.com>
Reviewed-by: Suzuki K Poulose <suzuki.poulose@arm.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
2019-04-24 15:36:22 +01:00

85 lines
2.0 KiB
C

// SPDX-License-Identifier: GPL-2.0
/*
* Copyright 2019 Arm Limited
* Author: Andrew Murray <Andrew.Murray@arm.com>
*/
#include <linux/kvm_host.h>
#include <linux/perf_event.h>
#include <asm/kvm_hyp.h>
/*
* Given the exclude_{host,guest} attributes, determine if we are going
* to need to switch counters at guest entry/exit.
*/
static bool kvm_pmu_switch_needed(struct perf_event_attr *attr)
{
/* Only switch if attributes are different */
return (attr->exclude_host != attr->exclude_guest);
}
/*
* Add events to track that we may want to switch at guest entry/exit
* time.
*/
void kvm_set_pmu_events(u32 set, struct perf_event_attr *attr)
{
struct kvm_host_data *ctx = this_cpu_ptr(&kvm_host_data);
if (!kvm_pmu_switch_needed(attr))
return;
if (!attr->exclude_host)
ctx->pmu_events.events_host |= set;
if (!attr->exclude_guest)
ctx->pmu_events.events_guest |= set;
}
/*
* Stop tracking events
*/
void kvm_clr_pmu_events(u32 clr)
{
struct kvm_host_data *ctx = this_cpu_ptr(&kvm_host_data);
ctx->pmu_events.events_host &= ~clr;
ctx->pmu_events.events_guest &= ~clr;
}
/**
* Disable host events, enable guest events
*/
bool __hyp_text __pmu_switch_to_guest(struct kvm_cpu_context *host_ctxt)
{
struct kvm_host_data *host;
struct kvm_pmu_events *pmu;
host = container_of(host_ctxt, struct kvm_host_data, host_ctxt);
pmu = &host->pmu_events;
if (pmu->events_host)
write_sysreg(pmu->events_host, pmcntenclr_el0);
if (pmu->events_guest)
write_sysreg(pmu->events_guest, pmcntenset_el0);
return (pmu->events_host || pmu->events_guest);
}
/**
* Disable guest events, enable host events
*/
void __hyp_text __pmu_switch_to_host(struct kvm_cpu_context *host_ctxt)
{
struct kvm_host_data *host;
struct kvm_pmu_events *pmu;
host = container_of(host_ctxt, struct kvm_host_data, host_ctxt);
pmu = &host->pmu_events;
if (pmu->events_guest)
write_sysreg(pmu->events_guest, pmcntenclr_el0);
if (pmu->events_host)
write_sysreg(pmu->events_host, pmcntenset_el0);
}