2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-27 14:43:58 +08:00
linux-next/Documentation/hwmon/max1668
David George 731b4cace1 hwmon: Driver for MAX1668
This patch adds support for MAX1668 and compatible temperature sensors.

Signed-off-by: David George <david.george@ska.ac.za>
[guenter.roeck@ericsson.com: minor cleanup of probe error path]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-07-28 00:17:32 -07:00

61 lines
2.3 KiB
Plaintext

Kernel driver max1668
=====================
Supported chips:
* Maxim MAX1668, MAX1805 and MAX1989
Prefix: 'max1668'
Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b, 0x4c, 0x4d, 0x4e
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX1668-MAX1989.pdf
Author:
David George <david.george@ska.ac.za>
Description
-----------
This driver implements support for the Maxim MAX1668, MAX1805 and MAX1989
chips.
The three devices are very similar, but the MAX1805 has a reduced feature
set; only two remote temperature inputs vs the four avaible on the other
two ICs.
The driver is able to distinguish between the devices and creates sysfs
entries as follows:
MAX1805, MAX1668 and MAX1989:
temp1_input ro local (ambient) temperature
temp1_max rw local temperature maximum threshold for alarm
temp1_max_alarm ro local temperature maximum threshold alarm
temp1_min rw local temperature minimum threshold for alarm
temp1_min_alarm ro local temperature minimum threshold alarm
temp2_input ro remote temperature 1
temp2_max rw remote temperature 1 maximum threshold for alarm
temp2_max_alarm ro remote temperature 1 maximum threshold alarm
temp2_min rw remote temperature 1 minimum threshold for alarm
temp2_min_alarm ro remote temperature 1 minimum threshold alarm
temp3_input ro remote temperature 2
temp3_max rw remote temperature 2 maximum threshold for alarm
temp3_max_alarm ro remote temperature 2 maximum threshold alarm
temp3_min rw remote temperature 2 minimum threshold for alarm
temp3_min_alarm ro remote temperature 2 minimum threshold alarm
MAX1668 and MAX1989 only:
temp4_input ro remote temperature 3
temp4_max rw remote temperature 3 maximum threshold for alarm
temp4_max_alarm ro remote temperature 3 maximum threshold alarm
temp4_min rw remote temperature 3 minimum threshold for alarm
temp4_min_alarm ro remote temperature 3 minimum threshold alarm
temp5_input ro remote temperature 4
temp5_max rw remote temperature 4 maximum threshold for alarm
temp5_max_alarm ro remote temperature 4 maximum threshold alarm
temp5_min rw remote temperature 4 minimum threshold for alarm
temp5_min_alarm ro remote temperature 4 minimum threshold alarm
Module Parameters
-----------------
* read_only: int
Set to non-zero if you wish to prevent write access to alarm thresholds.