2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-27 14:43:58 +08:00
linux-next/Documentation/hwmon/intel-m10-bmc-hwmon.rst
Xu Yilun 865e4fc013 hwmon: Add hwmon driver for Intel MAX 10 BMC
This patch adds hwmon functionality for Intel MAX 10 BMC chip. This BMC
chip connects to a set of sensor chips to monitor current, voltage,
thermal and power of different components on board. The BMC firmware is
responsible for sensor data sampling and recording in shared registers.
Host driver reads the sensor data from these shared registers and
exposes them to users as hwmon interfaces.

Signed-off-by: Xu Yilun <yilun.xu@intel.com>
Signed-off-by: Wu Hao <hao.wu@intel.com>
Signed-off-by: Matthew Gerlach <matthew.gerlach@linux.intel.com>
Signed-off-by: Tom Rix <trix@redhat.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/r/1600669071-26235-3-git-send-email-yilun.xu@intel.com
[groeck: Adjusted subject]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-10-04 08:40:10 -07:00

79 lines
2.9 KiB
ReStructuredText

.. SPDX-License-Identifier: GPL-2.0
Kernel driver intel-m10-bmc-hwmon
=================================
Supported chips:
* Intel MAX 10 BMC for Intel PAC N3000
Prefix: 'n3000bmc-hwmon'
Author: Xu Yilun <yilun.xu@intel.com>
Description
-----------
This driver adds the temperature, voltage, current and power reading
support for the Intel MAX 10 Board Management Controller (BMC) chip.
The BMC chip is integrated in some Intel Programmable Acceleration
Cards (PAC). It connects to a set of sensor chips to monitor the
sensor data of different components on the board. The BMC firmware is
responsible for sensor data sampling and recording in shared
registers. The host driver reads the sensor data from these shared
registers and exposes them to users as hwmon interfaces.
The BMC chip is implemented using the Intel MAX 10 CPLD. It could be
reprogramed to some variants in order to support different Intel
PACs. The driver is designed to be able to distinguish between the
variants, but now it only supports the BMC for Intel PAC N3000.
Sysfs attributes
----------------
The following attributes are supported:
- Intel MAX 10 BMC for Intel PAC N3000:
======================= =======================================================
tempX_input Temperature of the component (specified by tempX_label)
tempX_max Temperature maximum setpoint of the component
tempX_crit Temperature critical setpoint of the component
tempX_max_hyst Hysteresis for temperature maximum of the component
tempX_crit_hyst Hysteresis for temperature critical of the component
temp1_label "Board Temperature"
temp2_label "FPGA Die Temperature"
temp3_label "QSFP0 Temperature"
temp4_label "QSFP1 Temperature"
temp5_label "Retimer A Temperature"
temp6_label "Retimer A SerDes Temperature"
temp7_label "Retimer B Temperature"
temp8_label "Retimer B SerDes Temperature"
inX_input Measured voltage of the component (specified by
inX_label)
in0_label "QSFP0 Supply Voltage"
in1_label "QSFP1 Supply Voltage"
in2_label "FPGA Core Voltage"
in3_label "12V Backplane Voltage"
in4_label "1.2V Voltage"
in5_label "12V AUX Voltage"
in6_label "1.8V Voltage"
in7_label "3.3V Voltage"
currX_input Measured current of the component (specified by
currX_label)
curr1_label "FPGA Core Current"
curr2_label "12V Backplane Current"
curr3_label "12V AUX Current"
powerX_input Measured power of the component (specified by
powerX_label)
power1_label "Board Power"
======================= =======================================================
All the attributes are read-only.