2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-27 06:34:11 +08:00
Commit Graph

3 Commits

Author SHA1 Message Date
Ursula Braun
5da7e4d355 net/smc: return active RoCE port only
SMC requires an active ib port on the RoCE device.
smc_pnet_find_roce_resource() determines the matching RoCE device port
according to the configured PNET table. Do not return the found
RoCE device port, if it is not flagged active.

Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Reviewed-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-04-11 23:01:14 -04:00
Ursula Braun
249633a443 net/smc: remove useless smc_ib_devices_list check
The global event handler is created only, if the ib_device has already
been used by at least one link group. It is guaranteed that there exists
the corresponding entry in the smc_ib_devices list. Get rid of this
superfluous check.

Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Reviewed-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-04-11 23:01:14 -04:00
Thomas Richter
6812baabf2 smc: establish pnet table management
Connection creation with SMC-R starts through an internal
TCP-connection. The Ethernet interface for this TCP-connection is not
restricted to the Ethernet interface of a RoCE device. Any existing
Ethernet interface belonging to the same physical net can be used, as
long as there is a defined relation between the Ethernet interface and
some RoCE devices. This relation is defined with the help of an
identification string called "Physical Net ID" or short "pnet ID".
Information about defined pnet IDs and their related Ethernet
interfaces and RoCE devices is stored in the SMC-R pnet table.

A pnet table entry consists of the identifying pnet ID and the
associated network and IB device.
This patch adds pnet table configuration support using the
generic netlink message interface referring to network and IB device
by their names. Commands exist to add, delete, and display pnet table
entries, and to flush or display the entire pnet table.

There are cross-checks to verify whether the ethernet interfaces
or infiniband devices really exist in the system. If either device
is not available, the pnet ID entry is not created.
Loss of network devices and IB devices is also monitored;
a pnet ID entry is removed when an associated network or
IB device is removed.

Signed-off-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-01-09 16:07:38 -05:00