On my HP DL380 G5 system running a 64-bit kernel, loading the hpwdt
driver causes a crash because the driver attempts to ioremap an
invalid physical address. This is because the driver has an incorrect
definition of the SMBIOS table entry point structure: the table
address is only a 32-bit quantity, and making it a u64 means that the
high-order 32 bits end up containing garbage.
Correcting the structure definition fixes the driver so that it loads
without any problems on my system.
Signed-off-by: Roland Dreier <rolandd@cisco.com>
Acked-by: Thomas Mingarelli <Thomas.Mingarelli@hp.com>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Hp is providing a Hardware WatchDog Timer driver that will only work with the
specific HW Timer located in the HP ProLiant iLO 2 ASIC. The iLO 2 HW Timer
will generate a Non-maskable Interrupt (NMI) 9 seconds before physically
resetting the server, by removing power, so that the event can be logged to
the HP Integrated Management Log (IML), a Non-Volatile Random Access Memory
(NVRAM). The logging of the event is performed using the HP ProLiant ROM via
an Industry Standard access known as a BIOS Service Directory Entry.
Signed-off-by: Thomas Mingarelli <thomas.mingarelli@hp.com>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>