mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-25 05:34:00 +08:00
Some fixes for the new power-domain driver, including restricting
Rockchip Kconfig options, fixing a possible null-pointer and a typo in the dt-bindings. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1 iQEcBAABCAAGBQJWIlknAAoJEPOmecmc0R2BrTkH/3w+1ZZuvtfQmzBkPwJGJ9vJ zZFZLZqD0NADib8sOhFnJxTfxrhoE/Bfijqk4wPfjdKta2GABfljGbLDanQB8Yr9 Ip+fyflQ6cd925dEuPccHMbumZep+QuSIGYjOGFIuRbbjCdOY5MB+I2Yhvognwus Xh4FtjS7CL6ruotmyOcMtnpNDCAvc8NSwO7xBqxYRPcgd+DY8+86cD/dUpvmD4Kr pGtUXkfQpAjBhV9P6RuP63gO42JD1VMb7c6idd+B/tzbJxI08CTDolwqvyujVkHf KeRvu7g8qKKUwL5ffOImR4tR/T2o1wDLwfxuUJXW+mIVJa72qA+h90aNOhM2iC8= =Qk94 -----END PGP SIGNATURE----- Merge tag 'v4.4-rockchip-drivers2' of git://git.kernel.org/pub/scm/linux/kernel/git/mmind/linux-rockchip into next/drivers Some fixes for the new power-domain driver, including restricting Rockchip Kconfig options, fixing a possible null-pointer and a typo in the dt-bindings. * tag 'v4.4-rockchip-drivers2' of git://git.kernel.org/pub/scm/linux/kernel/git/mmind/linux-rockchip: dt-bindings: Correct paths in Rockchip power domains binding document soc: rockchip: power-domain: don't try to print the clock name in error case soc: rockchip: Restrict to ARCH_ROCKCHIP Signed-off-by: Olof Johansson <olof@lixom.net>
This commit is contained in:
commit
fe9990f9fd
@ -13,7 +13,7 @@ Required properties for power domain controller:
|
||||
|
||||
Required properties for power domain sub nodes:
|
||||
- reg: index of the power domain, should use macros in:
|
||||
"include/dt-bindings/power-domain/rk3288.h" - for RK3288 type power domain.
|
||||
"include/dt-bindings/power/rk3288-power.h" - for RK3288 type power domain.
|
||||
- clocks (optional): phandles to clocks which need to be enabled while power domain
|
||||
switches state.
|
||||
|
||||
@ -35,7 +35,7 @@ Node of a device using power domains must have a power-domains property,
|
||||
containing a phandle to the power device node and an index specifying which
|
||||
power domain to use.
|
||||
The index should use macros in:
|
||||
"include/dt-bindings/power-domain/rk3288.h" - for rk3288 type power domain.
|
||||
"include/dt-bindings/power/rk3288-power.h" - for rk3288 type power domain.
|
||||
|
||||
Example of the node using power domain:
|
||||
|
||||
|
@ -1,3 +1,5 @@
|
||||
if ARCH_ROCKCHIP || COMPILE_TEST
|
||||
|
||||
#
|
||||
# Rockchip Soc drivers
|
||||
#
|
||||
@ -12,3 +14,5 @@ config ROCKCHIP_PM_DOMAINS
|
||||
mode. The RK3288 PMU is dedicated for managing the power of the whole chip.
|
||||
|
||||
If unsure, say N.
|
||||
|
||||
endif
|
||||
|
@ -265,8 +265,8 @@ static int rockchip_pm_add_one_domain(struct rockchip_pmu *pmu,
|
||||
if (IS_ERR(clk)) {
|
||||
error = PTR_ERR(clk);
|
||||
dev_err(pmu->dev,
|
||||
"%s: failed to get clk %pC (index %d): %d\n",
|
||||
node->name, clk, i, error);
|
||||
"%s: failed to get clk at index %d: %d\n",
|
||||
node->name, i, error);
|
||||
goto err_out;
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user