mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-27 22:53:55 +08:00
KVM: s390: allow injecting all kinds of machine checks
Allow to specify CR14, logout area, external damage code and failed storage address. Since more then one machine check can be indicated to the guest at a time we need to combine all indication bits with already pending requests. Signed-off-by: Jens Freimann <jfrei@linux.vnet.ibm.com> Reviewed-by: Cornelia Huck <cornelia.huck@de.ibm.com> Reviewed-by: David Hildenbrand <dahi@linux.vnet.ibm.com> Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
This commit is contained in:
parent
383d0b0501
commit
fc2020cfe9
@ -1063,11 +1063,19 @@ static int __inject_mchk(struct kvm_vcpu *vcpu, struct kvm_s390_irq *irq)
|
||||
mchk->mcic, 2);
|
||||
|
||||
/*
|
||||
* Combine mcic with previously injected machine checks and
|
||||
* indicate them all together as described in the Principles
|
||||
* of Operation, Chapter 11, Interruption action
|
||||
* Because repressible machine checks can be indicated along with
|
||||
* exigent machine checks (PoP, Chapter 11, Interruption action)
|
||||
* we need to combine cr14, mcic and external damage code.
|
||||
* Failing storage address and the logout area should not be or'ed
|
||||
* together, we just indicate the last occurrence of the corresponding
|
||||
* machine check
|
||||
*/
|
||||
mchk->cr14 |= irq->u.mchk.cr14;
|
||||
mchk->mcic |= irq->u.mchk.mcic;
|
||||
mchk->ext_damage_code |= irq->u.mchk.ext_damage_code;
|
||||
mchk->failing_storage_address = irq->u.mchk.failing_storage_address;
|
||||
memcpy(&mchk->fixed_logout, &irq->u.mchk.fixed_logout,
|
||||
sizeof(mchk->fixed_logout));
|
||||
if (mchk->mcic & MCHK_EX_MASK)
|
||||
set_bit(IRQ_PEND_MCHK_EX, &li->pending_irqs);
|
||||
else if (mchk->mcic & MCHK_REP_MASK)
|
||||
|
Loading…
Reference in New Issue
Block a user