iio: adc: ti-ads1015: enable conversion when CONFIG_PM is not set
The ADS1015 device have two operating modes, continuous conversion mode and single-shot mode. This driver assumes that the continuous conversion mode is selected by runtime resume callback when the ADC result is requested. If CONFIG_PM is disabled, the device is always in the default single-shot mode and no one begins a single conversion. So the conversion register doesn't contain valid ADC result. Fix it by changing the continuous mode in probe function. Cc: Daniel Baluta <daniel.baluta@gmail.com> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
8d0e8e7956
commit
e8245c6835
@ -623,6 +623,13 @@ static int ads1015_probe(struct i2c_client *client,
|
||||
dev_err(&client->dev, "iio triggered buffer setup failed\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
ret = regmap_update_bits(data->regmap, ADS1015_CFG_REG,
|
||||
ADS1015_CFG_MOD_MASK,
|
||||
ADS1015_CONTINUOUS << ADS1015_CFG_MOD_SHIFT);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
ret = pm_runtime_set_active(&client->dev);
|
||||
if (ret)
|
||||
goto err_buffer_cleanup;
|
||||
|