mirror of
https://github.com/edk2-porting/linux-next.git
synced 2025-01-08 21:53:54 +08:00
ARM: dts: r8a7791: Correct critical CPU temperature
The R-Car M2W hardware manual states that Tc = –40°C to +105°C. The
thermal sensor has an accuracy of ±5°C and there can be a temperature
difference of 1 or 2 degrees between Tjmax and the thermal sensor due
to the location of the latter.
This means that 95°C is a safer value to use.
Fixes: cac68a56e3
("ARM: dts: r8a7791: enable to use thermal-zone")
Signed-off-by: Chris Paterson <chris.paterson2@renesas.com>
Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
This commit is contained in:
parent
fcab5651fa
commit
e4fdf59bcc
@ -92,7 +92,7 @@
|
||||
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <115000>;
|
||||
temperature = <95000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
|
Loading…