thermal: rcar_thermal: Remove temperature bound
The hardware manual states that the operation of the sensor is not guaranteed outside the range of -45°C to 125°C, not that the readings are invalid. Remove the bound check and try to deliver temperature readings even if we are outside the guaranteed operation range. Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20200117160554.3812787-2-niklas.soderlund+renesas@ragnatech.se
This commit is contained in:
parent
35709c4ee7
commit
dff6d4f805
@ -275,12 +275,7 @@ static int rcar_thermal_get_current_temp(struct rcar_thermal_priv *priv,
|
||||
tmp = MCELSIUS((priv->ctemp * 5) - 60);
|
||||
mutex_unlock(&priv->lock);
|
||||
|
||||
if ((tmp < MCELSIUS(-45)) || (tmp > MCELSIUS(125))) {
|
||||
struct device *dev = rcar_priv_to_dev(priv);
|
||||
|
||||
dev_err(dev, "it couldn't measure temperature correctly\n");
|
||||
return -EIO;
|
||||
}
|
||||
/* Guaranteed operating range is -45C to 125C. */
|
||||
|
||||
*temp = tmp;
|
||||
|
||||
|