iommu/ipmmu-vmsa: Add r8a7795 DT binding

Update the IPMMU DT binding documentation to include the r8a7795 compat
string as well as the "renesas,ipmmu-main" property that on r8a7795 will
be used to describe the topology and the relationship between the various
cache IPMMU instances and the main IPMMU.

Signed-off-by: Magnus Damm <damm+renesas@opensource.se>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
This commit is contained in:
Magnus Damm 2016-02-29 23:33:09 +09:00 committed by Joerg Roedel
parent 9015ba456c
commit d4e42e72e7

View File

@ -7,23 +7,34 @@ connected to the IPMMU through a port called micro-TLB.
Required Properties:
- compatible: Must contain SoC-specific and generic entries from below.
- compatible: Must contain SoC-specific and generic entry below in case
the device is compatible with the R-Car Gen2 VMSA-compatible IPMMU.
- "renesas,ipmmu-r8a73a4" for the R8A73A4 (R-Mobile APE6) IPMMU.
- "renesas,ipmmu-r8a7790" for the R8A7790 (R-Car H2) IPMMU.
- "renesas,ipmmu-r8a7791" for the R8A7791 (R-Car M2-W) IPMMU.
- "renesas,ipmmu-r8a7793" for the R8A7793 (R-Car M2-N) IPMMU.
- "renesas,ipmmu-r8a7794" for the R8A7794 (R-Car E2) IPMMU.
- "renesas,ipmmu-r8a7795" for the R8A7795 (R-Car H3) IPMMU.
- "renesas,ipmmu-vmsa" for generic R-Car Gen2 VMSA-compatible IPMMU.
- reg: Base address and size of the IPMMU registers.
- interrupts: Specifiers for the MMU fault interrupts. For instances that
support secure mode two interrupts must be specified, for non-secure and
secure mode, in that order. For instances that don't support secure mode a
single interrupt must be specified.
single interrupt must be specified. Not required for cache IPMMUs.
- #iommu-cells: Must be 1.
Optional properties:
- renesas,ipmmu-main: reference to the main IPMMU instance in two cells.
The first cell is a phandle to the main IPMMU and the second cell is
the interrupt bit number associated with the particular cache IPMMU device.
The interrupt bit number needs to match the main IPMMU IMSSTR register.
Only used by cache IPMMU instances.
Each bus master connected to an IPMMU must reference the IPMMU in its device
node with the following property: