mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-23 04:34:11 +08:00
tg3: Fix temperature reporting
The temperature registers appear to report values in degrees Celsius
while the hwmon API mandates values to be exposed in millidegrees
Celsius. Do the conversion so that the values reported by "sensors"
are correct.
Fixes: aed93e0bf4
("tg3: Add hwmon support for temperature")
Signed-off-by: Jean Delvare <jdelvare@suse.de>
Cc: Prashant Sreedharan <prashant@broadcom.com>
Cc: Michael Chan <mchan@broadcom.com>
Cc: stable@vger.kernel.org [v3.6+]
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
b6c6aedcbc
commit
d3d11fe08c
@ -10757,7 +10757,7 @@ static ssize_t tg3_show_temp(struct device *dev,
|
||||
tg3_ape_scratchpad_read(tp, &temperature, attr->index,
|
||||
sizeof(temperature));
|
||||
spin_unlock_bh(&tp->lock);
|
||||
return sprintf(buf, "%u\n", temperature);
|
||||
return sprintf(buf, "%u\n", temperature * 1000);
|
||||
}
|
||||
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user