Some of Intel Cherrytrail based platforms depend on PMC clock to be always on. Here couple of quirks to the driver to support affected hardware. The following is an automated git shortlog grouped by driver: pmc_atom: - Add several Beckhoff Automation boards to critclk_systems DMI table - Add Lex 3I380D industrial PC to critclk_systems DMI table -----BEGIN PGP SIGNATURE----- iQIzBAABCgAdFiEEqaflIX74DDDzMJJtb7wzTHR8rCgFAlzoFucACgkQb7wzTHR8 rChADBAAwdNr4g1NaSzOqGymunGN/ENxoWF/i4ABePAuk40OBn13rcZRXB2HDmdo oH5hbWsRdI/J6y0X8EVtdTjI06JacPbjBA0wsK7A/b/Z61L6WkaRn59/6OpYUbxp DA26VN6mRuoC7oqG7Qjv+y3KNBK6KV2ocrq9ojtOt14p2W6IkFl6NjD8F5Ug5X8U tojUlrhSJ3Ivlddvq8ya19vnC5Is8JUaU6yOCbcunNkFtKyAtfl9guAYhpqQkgB8 5Z114BmDH+oyhec/UaCPPAssb2JsmSwpLyIPPIhat0oflTrw7gQsctnSGYsUMuCn CT4Wlx2Ob0N4nt5GJ62EJ7akgIK5YBRVVqQr7EQXRgAHZAxD45CiNoLK3tDh6ZKn NA+gWd0D5C9CK4fGtoycxed8UTgJbutgKoIkYqwThMWjMYaR3Tv4G+nM/Oppo6eS rLjMWUSlXQJyUDWQH5SC5HNFNqlQBueULQDufZwOiQGCDWkLOlvqGA6/yV7YrdwW x8KQxPJT2nIHam1tQ54alFlCmVrYDlUx3WnEp4HX0mYEMWHbTkLdum0WdraXA6mj UsgmErOJYeKR6RJPpBsRsfqBSuk8eRGBMdRF0JSMG4sMAA/xqjM9l0kVzXwShFex L85SFLr+M3sBqb0QdVEkt4j4eFGxsmUVPSyF1lL7k8q0d4XJHAg= =kEst -----END PGP SIGNATURE----- Merge tag 'platform-drivers-x86-v5.2-2' of git://git.infradead.org/linux-platform-drivers-x86 Pull x86 platform driver fixes from Andy Shevchenko: "Some of Intel Cherrytrail based platforms depend on PMC clock to be always on. Here are a couple of quirks to the driver to support affected hardware" * tag 'platform-drivers-x86-v5.2-2' of git://git.infradead.org/linux-platform-drivers-x86: platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table platform/x86: pmc_atom: Add Lex 3I380D industrial PC to critclk_systems DMI table
This commit is contained in:
commit
c50bbf615f
@ -398,12 +398,45 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc)
|
||||
*/
|
||||
static const struct dmi_system_id critclk_systems[] = {
|
||||
{
|
||||
/* pmc_plt_clk0 is used for an external HSIC USB HUB */
|
||||
.ident = "MPL CEC1x",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
|
||||
.ident = "Lex 3I380D",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB3163",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6263",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6363",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
|
||||
},
|
||||
},
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|