mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-25 05:34:00 +08:00
power: supply: axp288_fuel_gauge: Only read PWR_OP_MODE, FG_LOW_CAP_REG regs once
Accessing registers on the AXP288 is quite expensive, so we should avoid doing unnecessary accesses. The FG_LOW_CAP_REG never changes underneath us, so we only need to read it once. Devices with an AXP288 do not have user-replace (let alone hot-swappable) batteries and the only bit we care about in the PWR_OP_MODE register is the CHRG_STAT_BAT_PRESENT bit, so we can get away with only reading the PWR_OP_MODE register once too. Note that the FG_LOW_CAP_REG is not marked volatile in the regmap, so we were effectively already reading it once. This change makes this explicit, this is done as preparation of a further patch which moves all remaining register accesses in fuel_gauge_get_property() out of that function. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
7eef3e6638
commit
c371d4491b
@ -111,6 +111,8 @@ struct axp288_fg_info {
|
||||
struct mutex lock;
|
||||
int status;
|
||||
int max_volt;
|
||||
int pwr_op;
|
||||
int low_cap;
|
||||
struct dentry *debug_file;
|
||||
};
|
||||
|
||||
@ -336,11 +338,7 @@ static int fuel_gauge_get_property(struct power_supply *ps,
|
||||
val->intval = PROP_CURR(value);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_PRESENT:
|
||||
ret = fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE);
|
||||
if (ret < 0)
|
||||
goto fuel_gauge_read_err;
|
||||
|
||||
if (ret & CHRG_STAT_BAT_PRESENT)
|
||||
if (info->pwr_op & CHRG_STAT_BAT_PRESENT)
|
||||
val->intval = 1;
|
||||
else
|
||||
val->intval = 0;
|
||||
@ -355,10 +353,7 @@ static int fuel_gauge_get_property(struct power_supply *ps,
|
||||
val->intval = (ret & FG_REP_CAP_VAL_MASK);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN:
|
||||
ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG);
|
||||
if (ret < 0)
|
||||
goto fuel_gauge_read_err;
|
||||
val->intval = (ret & 0x0f);
|
||||
val->intval = (info->low_cap & 0x0f);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_TECHNOLOGY:
|
||||
val->intval = POWER_SUPPLY_TECHNOLOGY_LION;
|
||||
@ -398,7 +393,7 @@ static int fuel_gauge_set_property(struct power_supply *ps,
|
||||
const union power_supply_propval *val)
|
||||
{
|
||||
struct axp288_fg_info *info = power_supply_get_drvdata(ps);
|
||||
int ret = 0;
|
||||
int new_low_cap, ret = 0;
|
||||
|
||||
mutex_lock(&info->lock);
|
||||
switch (prop) {
|
||||
@ -407,12 +402,12 @@ static int fuel_gauge_set_property(struct power_supply *ps,
|
||||
ret = -EINVAL;
|
||||
break;
|
||||
}
|
||||
ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG);
|
||||
if (ret < 0)
|
||||
break;
|
||||
ret &= 0xf0;
|
||||
ret |= (val->intval & 0xf);
|
||||
ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, ret);
|
||||
new_low_cap = info->low_cap;
|
||||
new_low_cap &= 0xf0;
|
||||
new_low_cap |= (val->intval & 0xf);
|
||||
ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, new_low_cap);
|
||||
if (ret == 0)
|
||||
info->low_cap = new_low_cap;
|
||||
break;
|
||||
default:
|
||||
ret = -EINVAL;
|
||||
@ -695,6 +690,16 @@ static int axp288_fuel_gauge_probe(struct platform_device *pdev)
|
||||
break;
|
||||
}
|
||||
|
||||
ret = fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE);
|
||||
if (ret < 0)
|
||||
goto out_free_iio_chan;
|
||||
info->pwr_op = ret;
|
||||
|
||||
ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG);
|
||||
if (ret < 0)
|
||||
goto out_free_iio_chan;
|
||||
info->low_cap = ret;
|
||||
|
||||
psy_cfg.drv_data = info;
|
||||
info->bat = power_supply_register(&pdev->dev, &fuel_gauge_desc, &psy_cfg);
|
||||
if (IS_ERR(info->bat)) {
|
||||
|
Loading…
Reference in New Issue