mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-22 12:14:01 +08:00
iio: light: cm32181: Handle CM3218 ACPI devices with 2 I2C resources
Some ACPI systems list 2 I2C resources for the CM3218 sensor. On these systems the first I2cSerialBus ACPI-resource points to the SMBus Alert Response Address (ARA, 0x0c) and the second I2cSerialBus ACPI-resource points to the actual CM3218 sensor address: Method (_CRS, 0, NotSerialized) // _CRS: Current Resource Settings { Name (SBUF, ResourceTemplate () { I2cSerialBusV2 (0x000C, ControllerInitiated, 0x00061A80, AddressingMode7Bit, "\\_SB.I2C3", 0x00, ResourceConsumer, , Exclusive, ) I2cSerialBusV2 (0x0048, ControllerInitiated, 0x00061A80, AddressingMode7Bit, "\\_SB.I2C3", 0x00, ResourceConsumer, , Exclusive, ) Interrupt (ResourceConsumer, Level, ActiveHigh, Exclusive, ,, ) { 0x00000033, } }) Return (SBUF) /* \_SB_.I2C3.ALSD._CRS.SBUF */ } Detect this and take the following step to deal with it: 1. When a SMBus Alert capable sensor has an Alert asserted, it will not respond on its actual I2C address. Read a byte from the ARA to clear any pending Alerts. 2. Create a "dummy" client for the actual I2C address and use that client to communicate with the sensor. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
b885d0fa67
commit
c1e62062ff
@ -52,6 +52,8 @@
|
||||
#define CM32181_CALIBSCALE_RESOLUTION 1000
|
||||
#define MLUX_PER_LUX 1000
|
||||
|
||||
#define SMBUS_ALERT_RESPONSE_ADDRESS 0x0c
|
||||
|
||||
static const u8 cm32181_reg[CM32181_CONF_REG_NUM] = {
|
||||
CM32181_REG_ADDR_CMD,
|
||||
};
|
||||
@ -336,6 +338,26 @@ static int cm32181_probe(struct i2c_client *client)
|
||||
if (!indio_dev)
|
||||
return -ENOMEM;
|
||||
|
||||
/*
|
||||
* Some ACPI systems list 2 I2C resources for the CM3218 sensor, the
|
||||
* SMBus Alert Response Address (ARA, 0x0c) and the actual I2C address.
|
||||
* Detect this and take the following step to deal with it:
|
||||
* 1. When a SMBus Alert capable sensor has an Alert asserted, it will
|
||||
* not respond on its actual I2C address. Read a byte from the ARA
|
||||
* to clear any pending Alerts.
|
||||
* 2. Create a "dummy" client for the actual I2C address and
|
||||
* use that client to communicate with the sensor.
|
||||
*/
|
||||
if (ACPI_HANDLE(dev) && client->addr == SMBUS_ALERT_RESPONSE_ADDRESS) {
|
||||
struct i2c_board_info board_info = { .type = "dummy" };
|
||||
|
||||
i2c_smbus_read_byte(client);
|
||||
|
||||
client = i2c_acpi_new_device(dev, 1, &board_info);
|
||||
if (IS_ERR(client))
|
||||
return PTR_ERR(client);
|
||||
}
|
||||
|
||||
cm32181 = iio_priv(indio_dev);
|
||||
cm32181->client = client;
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user