thermal: devfreq_cooling: change tracing function and arguments

Prepare for deleting the static and dynamic power calculation and clean
the trace function. These two fields are going to be removed in the next
changes.

Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Reviewed-by: Steven Rostedt (VMware) <rostedt@goodmis.org> # for tracing code
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201210143014.24685-2-lukasz.luba@arm.com
This commit is contained in:
Lukasz Luba 2020-12-10 14:30:10 +00:00 committed by Daniel Lezcano
parent ac35e6cb9e
commit b8643a5299
2 changed files with 10 additions and 12 deletions

View File

@ -277,8 +277,7 @@ static int devfreq_cooling_get_requested_power(struct thermal_cooling_device *cd
*power = dyn_power + static_power;
}
trace_thermal_power_devfreq_get_power(cdev, status, freq, dyn_power,
static_power, *power);
trace_thermal_power_devfreq_get_power(cdev, status, freq, *power);
return 0;
fail:

View File

@ -153,31 +153,30 @@ TRACE_EVENT(thermal_power_cpu_limit,
TRACE_EVENT(thermal_power_devfreq_get_power,
TP_PROTO(struct thermal_cooling_device *cdev,
struct devfreq_dev_status *status, unsigned long freq,
u32 dynamic_power, u32 static_power, u32 power),
u32 power),
TP_ARGS(cdev, status, freq, dynamic_power, static_power, power),
TP_ARGS(cdev, status, freq, power),
TP_STRUCT__entry(
__string(type, cdev->type )
__field(unsigned long, freq )
__field(u32, load )
__field(u32, dynamic_power )
__field(u32, static_power )
__field(u32, busy_time)
__field(u32, total_time)
__field(u32, power)
),
TP_fast_assign(
__assign_str(type, cdev->type);
__entry->freq = freq;
__entry->load = (100 * status->busy_time) / status->total_time;
__entry->dynamic_power = dynamic_power;
__entry->static_power = static_power;
__entry->busy_time = status->busy_time;
__entry->total_time = status->total_time;
__entry->power = power;
),
TP_printk("type=%s freq=%lu load=%u dynamic_power=%u static_power=%u power=%u",
TP_printk("type=%s freq=%lu load=%u power=%u",
__get_str(type), __entry->freq,
__entry->load, __entry->dynamic_power, __entry->static_power,
__entry->total_time == 0 ? 0 :
(100 * __entry->busy_time) / __entry->total_time,
__entry->power)
);