diff --git a/net/bridge/br_vlan.c b/net/bridge/br_vlan.c index f5b2aeebbfe9..bb98984cd27d 100644 --- a/net/bridge/br_vlan.c +++ b/net/bridge/br_vlan.c @@ -1281,6 +1281,8 @@ int br_vlan_get_info(const struct net_device *dev, u16 vid, p_vinfo->vid = vid; p_vinfo->flags = v->flags; + if (vid == br_get_pvid(vg)) + p_vinfo->flags |= BRIDGE_VLAN_INFO_PVID; return 0; } EXPORT_SYMBOL_GPL(br_vlan_get_info); diff --git a/net/dsa/tag_8021q.c b/net/dsa/tag_8021q.c index 6ebbd799c4eb..e44e6275b0a1 100644 --- a/net/dsa/tag_8021q.c +++ b/net/dsa/tag_8021q.c @@ -91,6 +91,79 @@ int dsa_8021q_rx_source_port(u16 vid) } EXPORT_SYMBOL_GPL(dsa_8021q_rx_source_port); +static int dsa_8021q_restore_pvid(struct dsa_switch *ds, int port) +{ + struct bridge_vlan_info vinfo; + struct net_device *slave; + u16 pvid; + int err; + + if (!dsa_is_user_port(ds, port)) + return 0; + + slave = ds->ports[port].slave; + + err = br_vlan_get_pvid(slave, &pvid); + if (err < 0) + /* There is no pvid on the bridge for this port, which is + * perfectly valid. Nothing to restore, bye-bye! + */ + return 0; + + err = br_vlan_get_info(slave, pvid, &vinfo); + if (err < 0) { + dev_err(ds->dev, "Couldn't determine PVID attributes\n"); + return err; + } + + return dsa_port_vid_add(&ds->ports[port], pvid, vinfo.flags); +} + +/* If @enabled is true, installs @vid with @flags into the switch port's HW + * filter. + * If @enabled is false, deletes @vid (ignores @flags) from the port. Had the + * user explicitly configured this @vid through the bridge core, then the @vid + * is installed again, but this time with the flags from the bridge layer. + */ +static int dsa_8021q_vid_apply(struct dsa_switch *ds, int port, u16 vid, + u16 flags, bool enabled) +{ + struct dsa_port *dp = &ds->ports[port]; + struct bridge_vlan_info vinfo; + int err; + + if (enabled) + return dsa_port_vid_add(dp, vid, flags); + + err = dsa_port_vid_del(dp, vid); + if (err < 0) + return err; + + /* Nothing to restore from the bridge for a non-user port. + * The CPU port VLANs are restored implicitly with the user ports, + * similar to how the bridge does in dsa_slave_vlan_add and + * dsa_slave_vlan_del. + */ + if (!dsa_is_user_port(ds, port)) + return 0; + + err = br_vlan_get_info(dp->slave, vid, &vinfo); + /* Couldn't determine bridge attributes for this vid, + * it means the bridge had not configured it. + */ + if (err < 0) + return 0; + + /* Restore the VID from the bridge */ + err = dsa_port_vid_add(dp, vid, vinfo.flags); + if (err < 0) + return err; + + vinfo.flags &= ~BRIDGE_VLAN_INFO_PVID; + + return dsa_port_vid_add(dp->cpu_dp, vid, vinfo.flags); +} + /* RX VLAN tagging (left) and TX VLAN tagging (right) setup shown for a single * front-panel switch port (here swp0). * @@ -146,8 +219,6 @@ EXPORT_SYMBOL_GPL(dsa_8021q_rx_source_port); int dsa_port_setup_8021q_tagging(struct dsa_switch *ds, int port, bool enabled) { int upstream = dsa_upstream_port(ds, port); - struct dsa_port *dp = &ds->ports[port]; - struct dsa_port *upstream_dp = &ds->ports[upstream]; u16 rx_vid = dsa_8021q_rx_vid(ds, port); u16 tx_vid = dsa_8021q_tx_vid(ds, port); int i, err; @@ -164,7 +235,6 @@ int dsa_port_setup_8021q_tagging(struct dsa_switch *ds, int port, bool enabled) * restrictions, so there are no concerns about leaking traffic. */ for (i = 0; i < ds->num_ports; i++) { - struct dsa_port *other_dp = &ds->ports[i]; u16 flags; if (i == upstream) @@ -177,10 +247,7 @@ int dsa_port_setup_8021q_tagging(struct dsa_switch *ds, int port, bool enabled) /* The RX VID is a regular VLAN on all others */ flags = BRIDGE_VLAN_INFO_UNTAGGED; - if (enabled) - err = dsa_port_vid_add(other_dp, rx_vid, flags); - else - err = dsa_port_vid_del(other_dp, rx_vid); + err = dsa_8021q_vid_apply(ds, i, rx_vid, flags, enabled); if (err) { dev_err(ds->dev, "Failed to apply RX VID %d to port %d: %d\n", rx_vid, port, err); @@ -191,10 +258,7 @@ int dsa_port_setup_8021q_tagging(struct dsa_switch *ds, int port, bool enabled) /* CPU port needs to see this port's RX VID * as tagged egress. */ - if (enabled) - err = dsa_port_vid_add(upstream_dp, rx_vid, 0); - else - err = dsa_port_vid_del(upstream_dp, rx_vid); + err = dsa_8021q_vid_apply(ds, upstream, rx_vid, 0, enabled); if (err) { dev_err(ds->dev, "Failed to apply RX VID %d to port %d: %d\n", rx_vid, port, err); @@ -202,26 +266,24 @@ int dsa_port_setup_8021q_tagging(struct dsa_switch *ds, int port, bool enabled) } /* Finally apply the TX VID on this port and on the CPU port */ - if (enabled) - err = dsa_port_vid_add(dp, tx_vid, BRIDGE_VLAN_INFO_UNTAGGED); - else - err = dsa_port_vid_del(dp, tx_vid); + err = dsa_8021q_vid_apply(ds, port, tx_vid, BRIDGE_VLAN_INFO_UNTAGGED, + enabled); if (err) { dev_err(ds->dev, "Failed to apply TX VID %d on port %d: %d\n", tx_vid, port, err); return err; } - if (enabled) - err = dsa_port_vid_add(upstream_dp, tx_vid, 0); - else - err = dsa_port_vid_del(upstream_dp, tx_vid); + err = dsa_8021q_vid_apply(ds, upstream, tx_vid, 0, enabled); if (err) { dev_err(ds->dev, "Failed to apply TX VID %d on port %d: %d\n", tx_vid, upstream, err); return err; } - return 0; + if (!enabled) + err = dsa_8021q_restore_pvid(ds, port); + + return err; } EXPORT_SYMBOL_GPL(dsa_port_setup_8021q_tagging);