ARM: mach-shmobile: PLL does not have to run constantly for HDMI
The PLLC2 clock on AP4 systems does not need to run constantly to be able to use HDMI. The HDMI hotplug interrupt works without the PLL too, after which all the necessary clocks will be turned on by the runtime PM. Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de> Signed-off-by: Paul Mundt <lethal@linux-sh.org>
This commit is contained in:
parent
fe78e68ab8
commit
a63666c146
@ -980,11 +980,6 @@ static void __init hdmi_init_pm_clock(void)
|
||||
goto out;
|
||||
}
|
||||
|
||||
ret = clk_enable(&sh7372_pllc2_clk);
|
||||
if (ret < 0) {
|
||||
pr_err("Cannot enable pllc2 clock\n");
|
||||
goto out;
|
||||
}
|
||||
pr_debug("PLLC2 set frequency %lu\n", rate);
|
||||
|
||||
ret = clk_set_parent(hdmi_ick, &sh7372_pllc2_clk);
|
||||
|
@ -458,12 +458,6 @@ static void __init hdmi_init_pm_clock(void)
|
||||
goto out;
|
||||
}
|
||||
|
||||
ret = clk_enable(&sh7372_pllc2_clk);
|
||||
if (ret < 0) {
|
||||
pr_err("Cannot enable pllc2 clock\n");
|
||||
goto out;
|
||||
}
|
||||
|
||||
pr_debug("PLLC2 set frequency %lu\n", rate);
|
||||
|
||||
ret = clk_set_parent(hdmi_ick, &sh7372_pllc2_clk);
|
||||
|