rtc: pcf85063: Always clear EXT_TEST from set_time
Power-on reset after the insertion of a battery does not always complete successfully, leading to corrupted register content. The EXT_TEST bit will stop the clock from running, but currently the driver will never recover. Safely handle the erroneous state by clearing EXT_TEST as part of the usual set_time method. Signed-off-by: Phil Elwell <phil@raspberrypi.com> Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> Link: https://lore.kernel.org/r/20211015111208.1757110-1-phil@raspberrypi.com
This commit is contained in:
parent
4c8a7b80d5
commit
9f08c9ed58
@ -34,6 +34,7 @@
|
||||
#define PCF85063_REG_CTRL1 0x00 /* status */
|
||||
#define PCF85063_REG_CTRL1_CAP_SEL BIT(0)
|
||||
#define PCF85063_REG_CTRL1_STOP BIT(5)
|
||||
#define PCF85063_REG_CTRL1_EXT_TEST BIT(7)
|
||||
|
||||
#define PCF85063_REG_CTRL2 0x01
|
||||
#define PCF85063_CTRL2_AF BIT(6)
|
||||
@ -117,6 +118,7 @@ static int pcf85063_rtc_set_time(struct device *dev, struct rtc_time *tm)
|
||||
* reset state until all time/date registers are written
|
||||
*/
|
||||
rc = regmap_update_bits(pcf85063->regmap, PCF85063_REG_CTRL1,
|
||||
PCF85063_REG_CTRL1_EXT_TEST |
|
||||
PCF85063_REG_CTRL1_STOP,
|
||||
PCF85063_REG_CTRL1_STOP);
|
||||