2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-17 09:43:59 +08:00

ab8500-fg: Allow capacity to raise from 1% when charging

When battery capacity was going below 1% fg is not supposed
to report 0% unless we've got the LOW_BAT IRQ, no matter
what the FG-algorithm says. This made fg get stuck at 1% if
charger is connected when capacity is 1%.

Signed-off-by: Hakan BERG <hakan.berg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Srinidhi KASAGAR <srinidhi.kasagar@stericsson.com>
This commit is contained in:
Hakan Berg 2012-07-23 14:00:50 +02:00 committed by Lee Jones
parent 908fe8d6a5
commit 642776182c

View File

@ -1354,9 +1354,6 @@ static void ab8500_fg_check_capacity_limits(struct ab8500_fg *di, bool init)
* algorithm says.
*/
di->bat_cap.prev_percent = 1;
di->bat_cap.permille = 1;
di->bat_cap.prev_mah = 1;
di->bat_cap.mah = 1;
percent = 1;
changed = true;
@ -1768,9 +1765,10 @@ static void ab8500_fg_algorithm(struct ab8500_fg *di)
ab8500_fg_algorithm_discharging(di);
}
dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d "
dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d %d "
"%d %d %d %d %d %d %d\n",
di->bat_cap.max_mah_design,
di->bat_cap.max_mah,
di->bat_cap.mah,
di->bat_cap.permille,
di->bat_cap.level,