iio: hid-sensor-als: Fix return values

IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.

Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Sachin Kamat 2014-03-07 07:44:00 +00:00 committed by Jonathan Cameron
parent 5f25b41f7e
commit 5d24b0b37b

View File

@ -79,7 +79,6 @@ static int als_read_raw(struct iio_dev *indio_dev,
struct als_state *als_state = iio_priv(indio_dev);
int report_id = -1;
u32 address;
int ret;
int ret_type;
s32 poll_value;
@ -129,14 +128,12 @@ static int als_read_raw(struct iio_dev *indio_dev,
ret_type = IIO_VAL_INT;
break;
case IIO_CHAN_INFO_SAMP_FREQ:
ret = hid_sensor_read_samp_freq_value(
ret_type = hid_sensor_read_samp_freq_value(
&als_state->common_attributes, val, val2);
ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
case IIO_CHAN_INFO_HYSTERESIS:
ret = hid_sensor_read_raw_hyst_value(
ret_type = hid_sensor_read_raw_hyst_value(
&als_state->common_attributes, val, val2);
ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
default:
ret_type = -EINVAL;