mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-18 02:04:05 +08:00
hwmon: (f75375s) Disable setting DC fan control mode for F75373
F75373 does not support DC (linear voltage) fan control mode, so don't let the user set it. Cc: Riku Voipio <riku.voipio@iki.fi> Reviewed-by: Bjoern Gerhart <oss@extracloud.de> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
This commit is contained in:
parent
b1b561a228
commit
5cd3222a9f
@ -372,6 +372,10 @@ static ssize_t set_pwm_mode(struct device *dev, struct device_attribute *attr,
|
||||
if (!(val == 0 || val == 1))
|
||||
return -EINVAL;
|
||||
|
||||
/* F75373 does not support DC (linear voltage) fan control mode */
|
||||
if (data->kind == f75373 && val == 0)
|
||||
return -EINVAL;
|
||||
|
||||
mutex_lock(&data->update_lock);
|
||||
conf = f75375_read8(client, F75375_REG_CONFIG1);
|
||||
conf &= ~(1 << FAN_CTRL_LINEAR(nr));
|
||||
|
Loading…