mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-23 12:43:55 +08:00
Documentation: Add device tree bindings for Freescale i.MX GPC
The i.MX6 contains a power controller that controls power gating and sequencing for the SoC's power domains. Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de> Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
This commit is contained in:
parent
52c47b6341
commit
58e4a668be
59
Documentation/devicetree/bindings/power/fsl,imx-gpc.txt
Normal file
59
Documentation/devicetree/bindings/power/fsl,imx-gpc.txt
Normal file
@ -0,0 +1,59 @@
|
||||
Freescale i.MX General Power Controller
|
||||
=======================================
|
||||
|
||||
The i.MX6Q General Power Control (GPC) block contains DVFS load tracking
|
||||
counters and Power Gating Control (PGC) for the CPU and PU (GPU/VPU) power
|
||||
domains.
|
||||
|
||||
Required properties:
|
||||
- compatible: Should be "fsl,imx6q-gpc" or "fsl,imx6sl-gpc"
|
||||
- reg: should be register base and length as documented in the
|
||||
datasheet
|
||||
- interrupts: Should contain GPC interrupt request 1
|
||||
- pu-supply: Link to the LDO regulator powering the PU power domain
|
||||
- clocks: Clock phandles to devices in the PU power domain that need
|
||||
to be enabled during domain power-up for reset propagation.
|
||||
- #power-domain-cells: Should be 1, see below:
|
||||
|
||||
The gpc node is a power-controller as documented by the generic power domain
|
||||
bindings in Documentation/devicetree/bindings/power/power_domain.txt.
|
||||
|
||||
Example:
|
||||
|
||||
gpc: gpc@020dc000 {
|
||||
compatible = "fsl,imx6q-gpc";
|
||||
reg = <0x020dc000 0x4000>;
|
||||
interrupts = <0 89 IRQ_TYPE_LEVEL_HIGH>,
|
||||
<0 90 IRQ_TYPE_LEVEL_HIGH>;
|
||||
pu-supply = <®_pu>;
|
||||
clocks = <&clks IMX6QDL_CLK_GPU3D_CORE>,
|
||||
<&clks IMX6QDL_CLK_GPU3D_SHADER>,
|
||||
<&clks IMX6QDL_CLK_GPU2D_CORE>,
|
||||
<&clks IMX6QDL_CLK_GPU2D_AXI>,
|
||||
<&clks IMX6QDL_CLK_OPENVG_AXI>,
|
||||
<&clks IMX6QDL_CLK_VPU_AXI>;
|
||||
#power-domain-cells = <1>;
|
||||
};
|
||||
|
||||
|
||||
Specifying power domain for IP modules
|
||||
======================================
|
||||
|
||||
IP cores belonging to a power domain should contain a 'power-domains' property
|
||||
that is a phandle pointing to the gpc device node and a DOMAIN_INDEX specifying
|
||||
the power domain the device belongs to.
|
||||
|
||||
Example of a device that is part of the PU power domain:
|
||||
|
||||
vpu: vpu@02040000 {
|
||||
reg = <0x02040000 0x3c000>;
|
||||
/* ... */
|
||||
power-domains = <&gpc 1>;
|
||||
/* ... */
|
||||
};
|
||||
|
||||
The following DOMAIN_INDEX values are valid for i.MX6Q:
|
||||
ARM_DOMAIN 0
|
||||
PU_DOMAIN 1
|
||||
The following additional DOMAIN_INDEX value is valid for i.MX6SL:
|
||||
DISPLAY_DOMAIN 2
|