2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-12 15:24:00 +08:00

regulator: anatop: make sure regulator name is properly defined

For anatop regulator we must have a name accordingly. Make sure the name
is properly checked before using it to avoid a possible kernel NULL
point crash.

Signed-off-by: Dong Aisheng <aisheng.dong@nxp.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Dong Aisheng 2017-04-14 22:32:43 +08:00 committed by Mark Brown
parent 9bf9445481
commit 4af5924c02

View File

@ -198,6 +198,10 @@ static int anatop_regulator_probe(struct platform_device *pdev)
rdesc->owner = THIS_MODULE;
of_property_read_string(np, "regulator-name", &rdesc->name);
if (!rdesc->name) {
dev_err(dev, "failed to get a regulator-name\n");
return -EINVAL;
}
initdata = of_get_regulator_init_data(dev, np, rdesc);
if (!initdata)
@ -300,8 +304,7 @@ static int anatop_regulator_probe(struct platform_device *pdev)
sreg->sel = 22;
/* set the default voltage of the pcie phy to be 1.100v */
if (!sreg->sel && rdesc->name &&
!strcmp(rdesc->name, "vddpcie"))
if (!sreg->sel && !strcmp(rdesc->name, "vddpcie"))
sreg->sel = 0x10;
if (!sreg->bypass && !sreg->sel) {