mtd: devices: elm: check for hardware engine's design constraints
ELM hardware engine is used by BCH ecc-schemes for detecting and locating ECC errors. This patch adds the following checks for ELM hardware engine: - ELM internal buffers are of 1K, so it cannot process data with ecc-step-size > 1K. - ELM engine can execute upto maximum of 8 threads in parallel, so in *page-mode* (when complete page is processed in single iteration), ELM cannot support ecc-steps > 8. Signed-off-by: Pekon Gupta <pekon@ti.com> Reviewed-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com> Signed-off-by: Brian Norris <computersforpeace@gmail.com>
This commit is contained in:
parent
d9ba46d32c
commit
3f4eb14bdb
@ -103,7 +103,8 @@ static u32 elm_read_reg(struct elm_info *info, int offset)
|
||||
* @dev: ELM device
|
||||
* @bch_type: Type of BCH ecc
|
||||
*/
|
||||
int elm_config(struct device *dev, enum bch_ecc bch_type)
|
||||
int elm_config(struct device *dev, enum bch_ecc bch_type,
|
||||
int ecc_steps, int ecc_step_size, int ecc_syndrome_size)
|
||||
{
|
||||
u32 reg_val;
|
||||
struct elm_info *info = dev_get_drvdata(dev);
|
||||
@ -112,6 +113,16 @@ int elm_config(struct device *dev, enum bch_ecc bch_type)
|
||||
dev_err(dev, "Unable to configure elm - device not probed?\n");
|
||||
return -ENODEV;
|
||||
}
|
||||
/* ELM cannot detect ECC errors for chunks > 1KB */
|
||||
if (ecc_step_size > ((ELM_ECC_SIZE + 1) / 2)) {
|
||||
dev_err(dev, "unsupported config ecc-size=%d\n", ecc_step_size);
|
||||
return -EINVAL;
|
||||
}
|
||||
/* ELM support 8 error syndrome process */
|
||||
if (ecc_steps > ERROR_VECTOR_MAX) {
|
||||
dev_err(dev, "unsupported config ecc-step=%d\n", ecc_steps);
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
reg_val = (bch_type & ECC_BCH_LEVEL_MASK) | (ELM_ECC_SIZE << 16);
|
||||
elm_write_reg(info, ELM_LOCATION_CONFIG, reg_val);
|
||||
|
@ -1540,6 +1540,8 @@ static int is_elm_present(struct omap_nand_info *info,
|
||||
struct device_node *elm_node, enum bch_ecc bch_type)
|
||||
{
|
||||
struct platform_device *pdev;
|
||||
struct nand_ecc_ctrl *ecc = &info->nand.ecc;
|
||||
int err;
|
||||
/* check whether elm-id is passed via DT */
|
||||
if (!elm_node) {
|
||||
pr_err("nand: error: ELM DT node not found\n");
|
||||
@ -1553,9 +1555,10 @@ static int is_elm_present(struct omap_nand_info *info,
|
||||
}
|
||||
/* ELM module available, now configure it */
|
||||
info->elm_dev = &pdev->dev;
|
||||
if (elm_config(info->elm_dev, bch_type))
|
||||
return -ENODEV;
|
||||
return 0;
|
||||
err = elm_config(info->elm_dev, bch_type,
|
||||
(info->mtd.writesize / ecc->size), ecc->size, ecc->bytes);
|
||||
|
||||
return err;
|
||||
}
|
||||
#endif /* CONFIG_MTD_NAND_ECC_BCH */
|
||||
|
||||
|
@ -50,5 +50,6 @@ struct elm_errorvec {
|
||||
|
||||
void elm_decode_bch_error_page(struct device *dev, u8 *ecc_calc,
|
||||
struct elm_errorvec *err_vec);
|
||||
int elm_config(struct device *dev, enum bch_ecc bch_type);
|
||||
int elm_config(struct device *dev, enum bch_ecc bch_type,
|
||||
int ecc_steps, int ecc_step_size, int ecc_syndrome_size);
|
||||
#endif /* __ELM_H */
|
||||
|