mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-25 05:34:00 +08:00
platform/x86: pmc_atom: Add Lex 3I380D industrial PC to critclk_systems DMI table
The Lex 3I380D industrial PC has 4 ethernet controllers on board
which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems
DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks
as CLK_CRITICAL and they will not get turned off.
Fixes: 648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reported-and-tested-by: Semyon Verchenko <semverchenko@factor-ts.ru>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
parent
a188339ca5
commit
3d0818f5eb
@ -398,12 +398,21 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc)
|
||||
*/
|
||||
static const struct dmi_system_id critclk_systems[] = {
|
||||
{
|
||||
/* pmc_plt_clk0 is used for an external HSIC USB HUB */
|
||||
.ident = "MPL CEC1x",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
|
||||
.ident = "Lex 3I380D",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
|
||||
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
|
||||
},
|
||||
},
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user