mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-11-17 07:04:01 +08:00
blkcg: make CONFIG_BLK_CGROUP bool
Block cgroup core can be built as module; however, it isn't too useful as blk-throttle can only be built-in and cfq-iosched is usually the default built-in scheduler. Scheduled blkcg cleanup requires calling into blkcg from block core. To simplify that, disallow building blkcg as module by making CONFIG_BLK_CGROUP bool. If building blkcg core as module really matters, which I doubt, we can revisit it after blkcg API cleanup. -v2: Vivek pointed out that IOSCHED_CFQ was incorrectly updated to depend on BLK_CGROUP. Fixed. Signed-off-by: Tejun Heo <tj@kernel.org> Cc: Vivek Goyal <vgoyal@redhat.com> Signed-off-by: Jens Axboe <axboe@kernel.dk>
This commit is contained in:
parent
b855b04a0b
commit
32e380aedc
@ -23,8 +23,6 @@ config IOSCHED_DEADLINE
|
||||
|
||||
config IOSCHED_CFQ
|
||||
tristate "CFQ I/O scheduler"
|
||||
# If BLK_CGROUP is a module, CFQ has to be built as module.
|
||||
depends on (BLK_CGROUP=m && m) || !BLK_CGROUP || BLK_CGROUP=y
|
||||
default y
|
||||
---help---
|
||||
The CFQ I/O scheduler tries to distribute bandwidth equally
|
||||
@ -34,8 +32,6 @@ config IOSCHED_CFQ
|
||||
|
||||
This is the default I/O scheduler.
|
||||
|
||||
Note: If BLK_CGROUP=m, then CFQ can be built only as module.
|
||||
|
||||
config CFQ_GROUP_IOSCHED
|
||||
bool "CFQ Group Scheduling support"
|
||||
depends on IOSCHED_CFQ && BLK_CGROUP
|
||||
|
@ -50,10 +50,7 @@ struct cgroup_subsys blkio_subsys = {
|
||||
.attach = blkiocg_attach,
|
||||
.destroy = blkiocg_destroy,
|
||||
.populate = blkiocg_populate,
|
||||
#ifdef CONFIG_BLK_CGROUP
|
||||
/* note: blkio_subsys_id is otherwise defined in blk-cgroup.h */
|
||||
.subsys_id = blkio_subsys_id,
|
||||
#endif
|
||||
.use_id = 1,
|
||||
.module = THIS_MODULE,
|
||||
};
|
||||
@ -1679,17 +1676,3 @@ void blkio_policy_unregister(struct blkio_policy_type *blkiop)
|
||||
spin_unlock(&blkio_list_lock);
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(blkio_policy_unregister);
|
||||
|
||||
static int __init init_cgroup_blkio(void)
|
||||
{
|
||||
return cgroup_load_subsys(&blkio_subsys);
|
||||
}
|
||||
|
||||
static void __exit exit_cgroup_blkio(void)
|
||||
{
|
||||
cgroup_unload_subsys(&blkio_subsys);
|
||||
}
|
||||
|
||||
module_init(init_cgroup_blkio);
|
||||
module_exit(exit_cgroup_blkio);
|
||||
MODULE_LICENSE("GPL");
|
||||
|
@ -24,13 +24,7 @@ enum blkio_policy_id {
|
||||
/* Max limits for throttle policy */
|
||||
#define THROTL_IOPS_MAX UINT_MAX
|
||||
|
||||
#if defined(CONFIG_BLK_CGROUP) || defined(CONFIG_BLK_CGROUP_MODULE)
|
||||
|
||||
#ifndef CONFIG_BLK_CGROUP
|
||||
/* When blk-cgroup is a module, its subsys_id isn't a compile-time constant */
|
||||
extern struct cgroup_subsys blkio_subsys;
|
||||
#define blkio_subsys_id blkio_subsys.subsys_id
|
||||
#endif
|
||||
#ifdef CONFIG_BLK_CGROUP
|
||||
|
||||
enum stat_type {
|
||||
/* Total time spent (in ns) between request dispatch to the driver and
|
||||
@ -303,7 +297,7 @@ static inline void blkiocg_update_idle_time_stats(struct blkio_group *blkg) {}
|
||||
static inline void blkiocg_set_start_empty_time(struct blkio_group *blkg) {}
|
||||
#endif
|
||||
|
||||
#if defined(CONFIG_BLK_CGROUP) || defined(CONFIG_BLK_CGROUP_MODULE)
|
||||
#ifdef CONFIG_BLK_CGROUP
|
||||
extern struct blkio_cgroup blkio_root_cgroup;
|
||||
extern struct blkio_cgroup *cgroup_to_blkio_cgroup(struct cgroup *cgroup);
|
||||
extern struct blkio_cgroup *task_blkio_cgroup(struct task_struct *tsk);
|
||||
|
@ -766,7 +766,7 @@ config RT_GROUP_SCHED
|
||||
endif #CGROUP_SCHED
|
||||
|
||||
config BLK_CGROUP
|
||||
tristate "Block IO controller"
|
||||
bool "Block IO controller"
|
||||
depends on BLOCK
|
||||
default n
|
||||
---help---
|
||||
|
Loading…
Reference in New Issue
Block a user