mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-17 09:43:59 +08:00
ab8500-btemp: Defer btemp filtering while initialising
Due to btemp filtering enabled during init, temp values reported to charge algorithm driver started from 0. As a result,charge algorithm was going into wrong state and charging was stopped. Signed-off-by: Rupesh Kumar <rupesh.kumar@stericsson.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com> Reviewed-by: Martin SJOBLOM <martin.w.sjoblom@stericsson.com> Reviewed-by: Philippe LANGLAIS <philippe.langlais@stericsson.com>
This commit is contained in:
parent
db43e6c473
commit
2c4c40ac00
@ -609,7 +609,6 @@ static void ab8500_btemp_periodic_work(struct work_struct *work)
|
||||
struct ab8500_btemp, btemp_periodic_work.work);
|
||||
|
||||
if (!di->initialized) {
|
||||
di->initialized = true;
|
||||
/* Identify the battery */
|
||||
if (ab8500_btemp_id(di) < 0)
|
||||
dev_warn(di->dev, "failed to identify the battery\n");
|
||||
@ -622,8 +621,9 @@ static void ab8500_btemp_periodic_work(struct work_struct *work)
|
||||
* same temperature. Else only allow 1 degree change from previous
|
||||
* reported value in the direction of the new measurement.
|
||||
*/
|
||||
if (bat_temp == di->prev_bat_temp || !di->initialized) {
|
||||
if (di->bat_temp != di->prev_bat_temp || !di->initialized) {
|
||||
if ((bat_temp == di->prev_bat_temp) || !di->initialized) {
|
||||
if ((di->bat_temp != di->prev_bat_temp) || !di->initialized) {
|
||||
di->initialized = true;
|
||||
di->bat_temp = bat_temp;
|
||||
power_supply_changed(&di->btemp_psy);
|
||||
}
|
||||
|
Loading…
Reference in New Issue