dt-bindings: input: touchscreen: resistive-adc-touch: create bindings
Added bindings for generic resistive touchscreen ADC. Signed-off-by: Eugen Hristev <eugen.hristev@microchip.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
15e20eabd7
commit
1b5bd7d25c
@ -0,0 +1,30 @@
|
||||
Generic resistive touchscreen ADC
|
||||
|
||||
Required properties:
|
||||
|
||||
- compatible: must be "resistive-adc-touch"
|
||||
The device must be connected to an ADC device that provides channels for
|
||||
position measurement and optional pressure.
|
||||
Refer to ../iio/iio-bindings.txt for details
|
||||
- iio-channels: must have at least two channels connected to an ADC device.
|
||||
These should correspond to the channels exposed by the ADC device and should
|
||||
have the right index as the ADC device registers them. These channels
|
||||
represent the relative position on the "x" and "y" axes.
|
||||
- iio-channel-names: must have all the channels' names. Mandatory channels
|
||||
are "x" and "y".
|
||||
|
||||
Optional properties:
|
||||
- iio-channels: The third channel named "pressure" is optional and can be
|
||||
used if the ADC device also measures pressure besides position.
|
||||
If this channel is missing, pressure will be ignored and the touchscreen
|
||||
will only report position.
|
||||
- iio-channel-names: optional channel named "pressure".
|
||||
|
||||
Example:
|
||||
|
||||
resistive_touch: resistive_touch {
|
||||
compatible = "resistive-adc-touch";
|
||||
touchscreen-min-pressure = <50000>;
|
||||
io-channels = <&adc 24>, <&adc 25>, <&adc 26>;
|
||||
io-channel-names = "x", "y", "pressure";
|
||||
};
|