2
0
mirror of https://github.com/edk2-porting/linux-next.git synced 2024-12-25 05:34:00 +08:00

ARM: dts: thermal: exynos: Add documentation for Exynos SoC thermal bindings

Proper description for Exynos4 bindings added to Documentation/devicetree/
bindings. It adds description to use multiple TMU instances, optional voltage
supply node and optional shared register across multiple TMU's.

Acked-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Acked-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
This commit is contained in:
Amit Daniel Kachhap 2013-06-24 16:20:48 +05:30 committed by Eduardo Valentin
parent 498d22f616
commit 0e97194bcf

View File

@ -0,0 +1,55 @@
* Exynos Thermal Management Unit (TMU)
** Required properties:
- compatible : One of the following:
"samsung,exynos4412-tmu"
"samsung,exynos4210-tmu"
"samsung,exynos5250-tmu"
"samsung,exynos5440-tmu"
- interrupt-parent : The phandle for the interrupt controller
- reg : Address range of the thermal registers. For soc's which has multiple
instances of TMU and some registers are shared across all TMU's like
interrupt related then 2 set of register has to supplied. First set
belongs to each instance of TMU and second set belongs to common TMU
registers.
- interrupts : Should contain interrupt for thermal system
- clocks : The main clock for TMU device
- clock-names : Thermal system clock name
- vtmu-supply: This entry is optional and provides the regulator node supplying
voltage to TMU. If needed this entry can be placed inside
board/platform specific dts file.
Example 1):
tmu@100C0000 {
compatible = "samsung,exynos4412-tmu";
interrupt-parent = <&combiner>;
reg = <0x100C0000 0x100>;
interrupts = <2 4>;
clocks = <&clock 383>;
clock-names = "tmu_apbif";
status = "disabled";
vtmu-supply = <&tmu_regulator_node>;
};
Example 2):
tmuctrl_0: tmuctrl@160118 {
compatible = "samsung,exynos5440-tmu";
reg = <0x160118 0x230>, <0x160368 0x10>;
interrupts = <0 58 0>;
clocks = <&clock 21>;
clock-names = "tmu_apbif";
};
Note: For multi-instance tmu each instance should have an alias correctly
numbered in "aliases" node.
Example:
aliases {
tmuctrl0 = &tmuctrl_0;
tmuctrl1 = &tmuctrl_1;
tmuctrl2 = &tmuctrl_2;
};