mirror of
https://github.com/edk2-porting/linux-next.git
synced 2024-12-23 04:34:11 +08:00
[POWERPC] pseries: Print PCI slot location code on failure
The PCI error recovery code will printk diagnostic info when a PCI error event occurs. Change the messages to include the slot location code, which is how most sysadmins will know the device. Signed-off-by: Linas Vepstas <linas@austin.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
parent
379507181a
commit
0aa8d15b01
@ -261,16 +261,22 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
|
||||
struct pci_bus *frozen_bus;
|
||||
int rc = 0;
|
||||
enum pci_ers_result result = PCI_ERS_RESULT_NONE;
|
||||
const char *pci_str, *drv_str;
|
||||
const char *location, *pci_str, *drv_str;
|
||||
|
||||
frozen_dn = find_device_pe(event->dn);
|
||||
frozen_bus = pcibios_find_pci_bus(frozen_dn);
|
||||
|
||||
if (!frozen_dn) {
|
||||
printk(KERN_ERR "EEH: Error: Cannot find partition endpoint for %s\n",
|
||||
pci_name(event->dev));
|
||||
|
||||
location = (char *) get_property(event->dn, "ibm,loc-code", NULL);
|
||||
location = location ? location : "unknown";
|
||||
printk(KERN_ERR "EEH: Error: Cannot find partition endpoint "
|
||||
"for location=%s pci addr=%s\n",
|
||||
location, pci_name(event->dev));
|
||||
return NULL;
|
||||
}
|
||||
location = (char *) get_property(frozen_dn, "ibm,loc-code", NULL);
|
||||
location = location ? location : "unknown";
|
||||
|
||||
/* There are two different styles for coming up with the PE.
|
||||
* In the old style, it was the highest EEH-capable device
|
||||
@ -282,8 +288,9 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
|
||||
frozen_bus = pcibios_find_pci_bus (frozen_dn->parent);
|
||||
|
||||
if (!frozen_bus) {
|
||||
printk(KERN_ERR "EEH: Cannot find PCI bus for %s\n",
|
||||
frozen_dn->full_name);
|
||||
printk(KERN_ERR "EEH: Cannot find PCI bus "
|
||||
"for location=%s dn=%s\n",
|
||||
location, frozen_dn->full_name);
|
||||
return NULL;
|
||||
}
|
||||
|
||||
@ -318,8 +325,9 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
|
||||
|
||||
eeh_slot_error_detail(frozen_pdn, 1 /* Temporary Error */);
|
||||
printk(KERN_WARNING
|
||||
"EEH: This PCI device has failed %d times since last reboot: %s - %s\n",
|
||||
frozen_pdn->eeh_freeze_count, drv_str, pci_str);
|
||||
"EEH: This PCI device has failed %d times since last reboot: "
|
||||
"location=%s driver=%s pci addr=%s\n",
|
||||
frozen_pdn->eeh_freeze_count, location, drv_str, pci_str);
|
||||
|
||||
/* Walk the various device drivers attached to this slot through
|
||||
* a reset sequence, giving each an opportunity to do what it needs
|
||||
@ -368,17 +376,18 @@ excess_failures:
|
||||
* due to actual, failed cards.
|
||||
*/
|
||||
printk(KERN_ERR
|
||||
"EEH: PCI device %s - %s has failed %d times \n"
|
||||
"and has been permanently disabled. Please try reseating\n"
|
||||
"this device or replacing it.\n",
|
||||
drv_str, pci_str, frozen_pdn->eeh_freeze_count);
|
||||
"EEH: PCI device at location=%s driver=%s pci addr=%s \n"
|
||||
"has failed %d times and has been permanently disabled. \n"
|
||||
"Please try reseating this device or replacing it.\n",
|
||||
location, drv_str, pci_str, frozen_pdn->eeh_freeze_count);
|
||||
goto perm_error;
|
||||
|
||||
hard_fail:
|
||||
printk(KERN_ERR
|
||||
"EEH: Unable to recover from failure of PCI device %s - %s\n"
|
||||
"EEH: Unable to recover from failure of PCI device "
|
||||
"at location=%s driver=%s pci addr=%s \n"
|
||||
"Please try reseating this device or replacing it.\n",
|
||||
drv_str, pci_str);
|
||||
location, drv_str, pci_str);
|
||||
|
||||
perm_error:
|
||||
eeh_slot_error_detail(frozen_pdn, 2 /* Permanent Error */);
|
||||
|
Loading…
Reference in New Issue
Block a user