// This file contains the Power Management IC (PMIC)
|
|
// customer-modifiable ACPI configurations.
|
|
//
|
|
|
|
//******************************************
|
|
//Configs for Battery Manager Device: PMBT
|
|
//******************************************
|
|
//--------------------
|
|
//PMBT: Method(BBAT)
|
|
//--------------------
|
|
Name(BFCC, 13100) //* (mWh), Full Charge Capacity
|
|
Name(PCT1, 5) //* (% of FCC), Default Alert 1
|
|
Name(PCT2, 9) //* (% of FCC), Default Alert 2
|
|
|
|
//--------------------
|
|
//PMBT: Method(BMNR)
|
|
//--------------------
|
|
Name(CUST, "850_MTP") //* cust file identifier
|
|
|
|
//--------------------
|
|
//PMBT: Method(BPLT)
|
|
//--------------------
|
|
Name(VNOM, 3800) //* (mV), Nominal Battery Voltage
|
|
Name(VLOW, 3300) //* (mV), Low Battery Voltage
|
|
Name(EMPT, 3200) //* (mV), VCutOff
|
|
Name(DCMA, 900) //* (mA), DC Current
|
|
Name(BOCP, 4500) //* (mA), OCP current used in BCL
|
|
Name(BVLO, 3000) //* (mV), BCL low Vbatt
|
|
Name(BLOP, 20) //* (%), BCL Low batt percent notification
|
|
Name(BNOP, 22) //* (%), BCL normal batt percent notification
|
|
Name(IFGD, 50) //* (mA), FG Iterm delta; (iterm + this value) determines when FG report 100%
|
|
Name(VFGD, 50) //* (mV), CC to CV Vdelta; (Vfloat - this value) determine when FG report 100%
|
|
|
|
//--------------------------------
|
|
//PMBT: Method(BJTA)/Method(BAT1)
|
|
//--------------------------------
|
|
Name(VDD1, 4350) //* (mV), Battery-1: Float Voltage (Standard Zone)
|
|
Name(FCC1, 2100) //* (mA), Battery-1: Full Charge Current (Standard Zone)
|
|
Name(HCLI, 0) //* (degree C), hard-cold temperature limit
|
|
Name(SCLI, 10) //* (degree C), soft-cold temperature limit
|
|
Name(SHLI, 45) //* (degree C), soft-hot temperature limit
|
|
Name(HHLI, 55) //* (degree C), hard-hot temperature limit
|
|
Name(FVC1, 105) //* (mV), Float voltage compensation, when battery in JEITA soft-limit
|
|
Name(CCC1, 1000) //* (mA), Charge current compensation, when battery in JEITA soft-limit
|
|
|
|
//--------------------
|
|
//PMBT: Method(CTMC)
|
|
//--------------------
|
|
Name(RID2, 15000) //* (Ohm), min RID for NORMAL category: 15K
|
|
Name(RID3, 140000) //* (Ohm), max RID for NORMAL category: 140K
|