ddr: altera: Remove unnecessary ODT mode config

There is no point in resetting the ODT setting if the write test
failed, since the code will always retry the calibration and thus
reconfigure the ODT anyway OR the code will fail calibration and
halt.

Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Dinh Nguyen <dinguyen@opensource.altera.com>
Cc: Chin Liang See <clsee@altera.com>
This commit is contained in:
Marek Vasut 2016-04-04 19:10:12 +02:00
parent f5f8c411de
commit f3f777cdf0

View File

@ -1207,7 +1207,6 @@ rw_mgr_mem_calibrate_write_test(const u32 rank_bgn, const u32 write_group,
*bit_chk == param->write_correct_mask);
return *bit_chk == param->write_correct_mask;
} else {
set_rank_and_odt_mask(0, RW_MGR_ODT_MODE_OFF);
debug_cond(DLEVEL == 2,
"write_test(%u,%u,ONE) : %u != %i => %i\n",
write_group, use_dm, *bit_chk, 0, *bit_chk != 0);