RX 8025 RTC: analyze 12/24-hour mode flag in rtc_get().

Signed-off-by: Yuri Tikhonov <yur@emcraft.com>
This commit is contained in:
Yuri Tikhonov 2008-08-15 15:42:09 +02:00 committed by Wolfgang Denk
parent 3e3c026ed7
commit 5875d358f0

View File

@ -136,7 +136,11 @@ int rtc_get (struct rtc_time *tmp)
tmp->tm_sec = bcd2bin (sec & 0x7F);
tmp->tm_min = bcd2bin (min & 0x7F);
tmp->tm_hour = bcd2bin (hour & 0x3F);
if (rtc_read(RTC_CTL1_REG_ADDR) & RTC_CTL1_BIT_2412)
tmp->tm_hour = bcd2bin (hour & 0x3F);
else
tmp->tm_hour = bcd2bin (hour & 0x1F) % 12 +
((hour & 0x20) ? 12 : 0);
tmp->tm_mday = bcd2bin (mday & 0x3F);
tmp->tm_mon = bcd2bin (mon & 0x1F);
tmp->tm_year = bcd2bin (year) + ( bcd2bin (year) >= 70 ? 1900 : 2000);