mmc: sdhci: Fix MMC HS200 tuning command failures

This patch fixes the mmc tuning command failures
when tuning pattern data needs to read back for
comparision against the expected bit pattern.

Reported-by: Masahiro Yamada <yamada.masahiro@socionext.com>
Signed-off-by: Siva Durga Prasad Paladugu <siva.durga.paladugu@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Tested-by: Masahiro Yamada <yamada.masahiro@socionext.com>
This commit is contained in:
Siva Durga Prasad Paladugu 2018-06-13 11:43:01 +05:30 committed by Michal Simek
parent c7df098a71
commit 1a7414f626

View File

@ -161,8 +161,8 @@ static int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd,
/* We shouldn't wait for data inihibit for stop commands, even
though they might use busy signaling */
if (cmd->cmdidx == MMC_CMD_STOP_TRANSMISSION ||
cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK ||
cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK_HS200)
((cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK ||
cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK_HS200) && !data))
mask &= ~SDHCI_DATA_INHIBIT;
while (sdhci_readl(host, SDHCI_PRESENT_STATE) & mask) {
@ -184,8 +184,8 @@ static int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd,
sdhci_writel(host, SDHCI_INT_ALL_MASK, SDHCI_INT_STATUS);
mask = SDHCI_INT_RESPONSE;
if (cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK ||
cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK_HS200)
if ((cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK ||
cmd->cmdidx == MMC_CMD_SEND_TUNING_BLOCK_HS200) && !data)
mask = SDHCI_INT_DATA_AVAIL;
if (!(cmd->resp_type & MMC_RSP_PRESENT))