mirror of
https://github.com/systemd/systemd.git
synced 2024-11-23 18:23:32 +08:00
144 lines
6.9 KiB
XML
144 lines
6.9 KiB
XML
<?xml version='1.0'?>
|
|
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
|
|
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd" >
|
|
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
|
|
|
|
<refentry id="org.freedesktop.LogControl1"
|
|
xmlns:xi="http://www.w3.org/2001/XInclude">
|
|
<refentryinfo>
|
|
<title>org.freedesktop.LogControl1</title>
|
|
<productname>systemd</productname>
|
|
</refentryinfo>
|
|
|
|
<refmeta>
|
|
<refentrytitle>org.freedesktop.LogControl1</refentrytitle>
|
|
<manvolnum>5</manvolnum>
|
|
</refmeta>
|
|
|
|
<refnamediv>
|
|
<refname>org.freedesktop.LogControl1</refname>
|
|
<refpurpose>D-Bus interface to query and set logging configuration</refpurpose>
|
|
</refnamediv>
|
|
|
|
<refsect1>
|
|
<title>Introduction</title>
|
|
|
|
<para><interfacename>org.freedesktop.LogControl1</interfacename> is a generic interface that is intended
|
|
to be used by any daemon which allows the log level and target to be set over D-Bus. It is implemented by
|
|
various daemons that are part of the
|
|
<citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry> suite.</para>
|
|
|
|
<para>It is assumed that those settings are global for the whole program, so a fixed object path is
|
|
used. The interface should always be available under the path
|
|
<filename>/org/freedesktop/LogControl1</filename>.</para>
|
|
</refsect1>
|
|
|
|
<refsect1>
|
|
<title>Description</title>
|
|
|
|
<para>The following interface is exposed:</para>
|
|
|
|
<programlisting executable="systemd" node="/org/freedesktop/LogControl1" interface="org.freedesktop.LogControl1">
|
|
node /org/freedesktop/LogControl1 {
|
|
interface org.freedesktop.LogControl1 {
|
|
properties:
|
|
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
|
|
@org.freedesktop.systemd1.Privileged("true")
|
|
readwrite s LogLevel = '...';
|
|
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
|
|
@org.freedesktop.systemd1.Privileged("true")
|
|
readwrite s LogTarget = '...';
|
|
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
|
|
readonly s SyslogIdentifier = '...';
|
|
};
|
|
interface org.freedesktop.DBus.Peer { ... };
|
|
interface org.freedesktop.DBus.Introspectable { ... };
|
|
interface org.freedesktop.DBus.Properties { ... };
|
|
};
|
|
</programlisting>
|
|
|
|
<!--Autogenerated cross-references for systemd.directives, do not edit-->
|
|
|
|
<variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.LogControl1"/>
|
|
|
|
<variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.LogControl1"/>
|
|
|
|
<variablelist class="dbus-property" generated="True" extra-ref="LogLevel"/>
|
|
|
|
<variablelist class="dbus-property" generated="True" extra-ref="LogTarget"/>
|
|
|
|
<variablelist class="dbus-property" generated="True" extra-ref="SyslogIdentifier"/>
|
|
|
|
<!--End of Autogenerated section-->
|
|
|
|
<refsect2>
|
|
<title>Properties</title>
|
|
|
|
<para><varname>LogLevel</varname> describes the
|
|
<citerefentry project="man-pages"><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry>-style
|
|
log-level, and should be one of <literal>emerg</literal>, <literal>alert</literal>,
|
|
<literal>crit</literal>, <literal>err</literal>, <literal>warning</literal>, <literal>notice</literal>,
|
|
<literal>info</literal>, <literal>debug</literal>, in order of increasing verbosity.</para>
|
|
|
|
<para><varname>LogTarget</varname> describes the log target (mechanism). It should be one of
|
|
<literal>console</literal> (log to the console or standard output),
|
|
<literal>kmsg</literal> (log to the kernel ring buffer),
|
|
<literal>journal</literal> (log to the journal natively, see
|
|
<citerefentry><refentrytitle>systemd-journald.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>),
|
|
<literal>syslog</literal> (log using the
|
|
<citerefentry project="man-pages"><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry> call).
|
|
</para>
|
|
|
|
<para>Those two properties are writable, so they may be set by sufficiently privileged users.</para>
|
|
|
|
<para><varname>SyslogIdentifier</varname> is a read-only property that shows the "syslog identifier".
|
|
It is a short string that identifies the program that is the source of log messages that is passed to
|
|
the <citerefentry project="man-pages"><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry> call.
|
|
</para>
|
|
</refsect2>
|
|
</refsect1>
|
|
|
|
<refsect1>
|
|
<title>Tools</title>
|
|
|
|
<para><command>journalctl</command> option <option>-p</option>/<option>--priority=</option> may be used
|
|
to filter log messages by log level, option <option>-t</option>/<option>--identifier=</option> may be
|
|
used to by the syslog identifier, and filters like <literal>_TRANSPORT=syslog</literal>,
|
|
<literal>_TRANSPORT=journal</literal>, and <literal>_TRANSPORT=kernel</literal> may be used to filter
|
|
messages by the mechanism through which they reached <command>systemd-journald</command>.</para>
|
|
|
|
<para><command>systemctl log-level</command> and <command>systemctl log-target</command> verbs may be
|
|
used to query and set the <varname>LogLevel</varname> and <varname>LogTarget</varname> properties of the
|
|
service manager. <command>systemctl service-log-level</command> and <command>systemctl
|
|
service-log-target</command> may similarly be used for individual services. (Services must have the
|
|
<varname>BusName=</varname> property set and must implement the interface described here. See
|
|
<citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
|
for details about <varname>BusName=</varname>.)</para>
|
|
</refsect1>
|
|
|
|
<refsect1>
|
|
<title>Example</title>
|
|
|
|
<example>
|
|
<title>Create a simple listener on the bus that implements LogControl1</title>
|
|
|
|
<programlisting><xi:include href="logcontrol-example.c" parse="text"/></programlisting>
|
|
|
|
<para>This creates a simple server on the bus. It implements the LogControl1 interface by providing
|
|
the required properties and allowing to set the writable ones. It logs at the configured log level using
|
|
<citerefentry><refentrytitle>sd_journal_print</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
|
|
</example>
|
|
</refsect1>
|
|
|
|
<refsect1>
|
|
<title>See Also</title>
|
|
<para><simplelist type="inline">
|
|
<member><citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
|
|
<member><citerefentry><refentrytitle>journalctl</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
|
|
<member><citerefentry><refentrytitle>systemctl</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
|
|
<member><citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry></member>
|
|
<member><citerefentry project="man-pages"><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
|
|
</simplelist></para>
|
|
</refsect1>
|
|
</refentry>
|