I found that there are many spelling errors in the comments of qemu, so I used the spellcheck tool to check the spelling errors and finally found some spelling errors in the docs folder. Signed-off-by: zhaolichang <zhaolichang@huawei.com> Reviewed-by: Peter Maydell <peter.maydell@linaro.org> Message-Id: <20200917075029.313-4-zhaolichang@huawei.com> Signed-off-by: Laurent Vivier <laurent@vivier.eu>
410 lines
18 KiB
Plaintext
410 lines
18 KiB
Plaintext
= sPAPR Dynamic Reconfiguration =
|
|
|
|
sPAPR/"pseries" guests make use of a facility called dynamic-reconfiguration
|
|
to handle hotplugging of dynamic "physical" resources like PCI cards, or
|
|
"logical"/paravirtual resources like memory, CPUs, and "physical"
|
|
host-bridges, which are generally managed by the host/hypervisor and provided
|
|
to guests as virtualized resources. The specifics of dynamic-reconfiguration
|
|
are documented extensively in PAPR+ v2.7, Section 13.1. This document
|
|
provides a summary of that information as it applies to the implementation
|
|
within QEMU.
|
|
|
|
== Dynamic-reconfiguration Connectors ==
|
|
|
|
To manage hotplug/unplug of these resources, a firmware abstraction known as
|
|
a Dynamic Resource Connector (DRC) is used to assign a particular dynamic
|
|
resource to the guest, and provide an interface for the guest to manage
|
|
configuration/removal of the resource associated with it.
|
|
|
|
== Device-tree description of DRCs ==
|
|
|
|
A set of 4 Open Firmware device tree array properties are used to describe
|
|
the name/index/power-domain/type of each DRC allocated to a guest at
|
|
boot-time. There may be multiple sets of these arrays, rooted at different
|
|
paths in the device tree depending on the type of resource the DRCs manage.
|
|
|
|
In some cases, the DRCs themselves may be provided by a dynamic resource,
|
|
such as the DRCs managing PCI slots on a hotplugged PHB. In this case the
|
|
arrays would be fetched as part of the device tree retrieval interfaces
|
|
for hotplugged resources described under "Guest->Host interface".
|
|
|
|
The array properties are described below. Each entry/element in an array
|
|
describes the DRC identified by the element in the corresponding position
|
|
of ibm,drc-indexes:
|
|
|
|
ibm,drc-names:
|
|
first 4-bytes: BE-encoded integer denoting the number of entries
|
|
each entry: a NULL-terminated <name> string encoded as a byte array
|
|
|
|
<name> values for logical/virtual resources are defined in PAPR+ v2.7,
|
|
Section 13.5.2.4, and basically consist of the type of the resource
|
|
followed by a space and a numerical value that's unique across resources
|
|
of that type.
|
|
|
|
<name> values for "physical" resources such as PCI or VIO devices are
|
|
defined as being "location codes", which are the "location labels" of
|
|
each encapsulating device, starting from the chassis down to the
|
|
individual slot for the device, concatenated by a hyphen. This provides
|
|
a mapping of resources to a physical location in a chassis for debugging
|
|
purposes. For QEMU, this mapping is less important, so we assign a
|
|
location code that conforms to naming specifications, but is simply a
|
|
location label for the slot by itself to simplify the implementation.
|
|
The naming convention for location labels is documented in detail in
|
|
PAPR+ v2.7, Section 12.3.1.5, and in our case amounts to using "C<n>"
|
|
for PCI/VIO device slots, where <n> is unique across all PCI/VIO
|
|
device slots.
|
|
|
|
ibm,drc-indexes:
|
|
first 4-bytes: BE-encoded integer denoting the number of entries
|
|
each 4-byte entry: BE-encoded <index> integer that is unique across all DRCs
|
|
in the machine
|
|
|
|
<index> is arbitrary, but in the case of QEMU we try to maintain the
|
|
convention used to assign them to pSeries guests on pHyp:
|
|
|
|
bit[31:28]: integer encoding of <type>, where <type> is:
|
|
1 for CPU resource
|
|
2 for PHB resource
|
|
3 for VIO resource
|
|
4 for PCI resource
|
|
8 for Memory resource
|
|
bit[27:0]: integer encoding of <id>, where <id> is unique across
|
|
all resources of specified type
|
|
|
|
ibm,drc-power-domains:
|
|
first 4-bytes: BE-encoded integer denoting the number of entries
|
|
each 4-byte entry: 32-bit, BE-encoded <index> integer that specifies the
|
|
power domain the resource will be assigned to. In the case of QEMU
|
|
we associated all resources with a "live insertion" domain, where the
|
|
power is assumed to be managed automatically. The integer value for
|
|
this domain is a special value of -1.
|
|
|
|
|
|
ibm,drc-types:
|
|
first 4-bytes: BE-encoded integer denoting the number of entries
|
|
each entry: a NULL-terminated <type> string encoded as a byte array
|
|
|
|
<type> is assigned as follows:
|
|
"CPU" for a CPU
|
|
"PHB" for a physical host-bridge
|
|
"SLOT" for a VIO slot
|
|
"28" for a PCI slot
|
|
"MEM" for memory resource
|
|
|
|
== Guest->Host interface to manage dynamic resources ==
|
|
|
|
Each DRC is given a globally unique DRC Index, and resources associated with
|
|
a particular DRC are configured/managed by the guest via a number of RTAS
|
|
calls which reference individual DRCs based on the DRC index. This can be
|
|
considered the guest->host interface.
|
|
|
|
rtas-set-power-level:
|
|
arg[0]: integer identifying power domain
|
|
arg[1]: new power level for the domain, 0-100
|
|
output[0]: status, 0 on success
|
|
output[1]: power level after command
|
|
|
|
Set the power level for a specified power domain
|
|
|
|
rtas-get-power-level:
|
|
arg[0]: integer identifying power domain
|
|
output[0]: status, 0 on success
|
|
output[1]: current power level
|
|
|
|
Get the power level for a specified power domain
|
|
|
|
rtas-set-indicator:
|
|
arg[0]: integer identifying sensor/indicator type
|
|
arg[1]: index of sensor, for DR-related sensors this is generally the
|
|
DRC index
|
|
arg[2]: desired sensor value
|
|
output[0]: status, 0 on success
|
|
|
|
Set the state of an indicator or sensor. For the purpose of this document we
|
|
focus on the indicator/sensor types associated with a DRC. The types are:
|
|
|
|
9001: isolation-state, controls/indicates whether a device has been made
|
|
accessible to a guest
|
|
|
|
supported sensor values:
|
|
0: isolate, device is made unaccessible by guest OS
|
|
1: unisolate, device is made available to guest OS
|
|
|
|
9002: dr-indicator, controls "visual" indicator associated with device
|
|
|
|
supported sensor values:
|
|
0: inactive, resource may be safely removed
|
|
1: active, resource is in use and cannot be safely removed
|
|
2: identify, used to visually identify slot for interactive hotplug
|
|
3: action, in most cases, used in the same manner as identify
|
|
|
|
9003: allocation-state, generally only used for "logical" DR resources to
|
|
request the allocation/deallocation of a resource prior to acquiring
|
|
it via isolation-state->unisolate, or after releasing it via
|
|
isolation-state->isolate, respectively. for "physical" DR (like PCI
|
|
hotplug/unplug) the pre-allocation of the resource is implied and
|
|
this sensor is unused.
|
|
|
|
supported sensor values:
|
|
0: unusable, tell firmware/system the resource can be
|
|
unallocated/reclaimed and added back to the system resource pool
|
|
1: usable, request the resource be allocated/reserved for use by
|
|
guest OS
|
|
2: exchange, used to allocate a spare resource to use for fail-over
|
|
in certain situations. unused in QEMU
|
|
3: recover, used to reclaim a previously allocated resource that's
|
|
not currently allocated to the guest OS. unused in QEMU
|
|
|
|
rtas-get-sensor-state:
|
|
arg[0]: integer identifying sensor/indicator type
|
|
arg[1]: index of sensor, for DR-related sensors this is generally the
|
|
DRC index
|
|
output[0]: status, 0 on success
|
|
|
|
Used to read an indicator or sensor value.
|
|
|
|
For DR-related operations, the only noteworthy sensor is dr-entity-sense,
|
|
which has a type value of 9003, as allocation-state does in the case of
|
|
rtas-set-indicator. The semantics/encodings of the sensor values are distinct
|
|
however:
|
|
|
|
supported sensor values for dr-entity-sense (9003) sensor:
|
|
0: empty,
|
|
for physical resources: DRC/slot is empty
|
|
for logical resources: unused
|
|
1: present,
|
|
for physical resources: DRC/slot is populated with a device/resource
|
|
for logical resources: resource has been allocated to the DRC
|
|
2: unusable,
|
|
for physical resources: unused
|
|
for logical resources: DRC has no resource allocated to it
|
|
3: exchange,
|
|
for physical resources: unused
|
|
for logical resources: resource available for exchange (see
|
|
allocation-state sensor semantics above)
|
|
4: recovery,
|
|
for physical resources: unused
|
|
for logical resources: resource available for recovery (see
|
|
allocation-state sensor semantics above)
|
|
|
|
rtas-ibm-configure-connector:
|
|
arg[0]: guest physical address of 4096-byte work area buffer
|
|
arg[1]: 0, or address of additional 4096-byte work area buffer. only non-zero
|
|
if a prior RTAS response indicated a need for additional memory
|
|
output[0]: status:
|
|
0: completed transmittal of device-tree node
|
|
1: instruct guest to prepare for next DT sibling node
|
|
2: instruct guest to prepare for next DT child node
|
|
3: instruct guest to prepare for next DT property
|
|
4: instruct guest to ascend to parent DT node
|
|
5: instruct guest to provide additional work-area buffer
|
|
via arg[1]
|
|
990x: instruct guest that operation took too long and to try
|
|
again later
|
|
|
|
Used to fetch an OF device-tree description of the resource associated with
|
|
a particular DRC. The DRC index is encoded in the first 4-bytes of the first
|
|
work area buffer.
|
|
|
|
Work area layout, using 4-byte offsets:
|
|
wa[0]: DRC index of the DRC to fetch device-tree nodes from
|
|
wa[1]: 0 (hard-coded)
|
|
wa[2]: for next-sibling/next-child response:
|
|
wa offset of null-terminated string denoting the new node's name
|
|
for next-property response:
|
|
wa offset of null-terminated string denoting new property's name
|
|
wa[3]: for next-property response (unused otherwise):
|
|
byte-length of new property's value
|
|
wa[4]: for next-property response (unused otherwise):
|
|
new property's value, encoded as an OFDT-compatible byte array
|
|
|
|
== hotplug/unplug events ==
|
|
|
|
For most DR operations, the hypervisor will issue host->guest add/remove events
|
|
using the EPOW/check-exception notification framework, where the host issues a
|
|
check-exception interrupt, then provides an RTAS event log via an
|
|
rtas-check-exception call issued by the guest in response. This framework is
|
|
documented by PAPR+ v2.7, and already use in by QEMU for generating powerdown
|
|
requests via EPOW events.
|
|
|
|
For DR, this framework has been extended to include hotplug events, which were
|
|
previously unneeded due to direct manipulation of DR-related guest userspace
|
|
tools by host-level management such as an HMC. This level of management is not
|
|
applicable to PowerKVM, hence the reason for extending the notification
|
|
framework to support hotplug events.
|
|
|
|
The format for these EPOW-signalled events is described below under
|
|
"hotplug/unplug event structure". Note that these events are not
|
|
formally part of the PAPR+ specification, and have been superseded by a
|
|
newer format, also described below under "hotplug/unplug event structure",
|
|
and so are now deemed a "legacy" format. The formats are similar, but the
|
|
"modern" format contains additional fields/flags, which are denoted for the
|
|
purposes of this documentation with "#ifdef GUEST_SUPPORTS_MODERN" guards.
|
|
|
|
QEMU should assume support only for "legacy" fields/flags unless the guest
|
|
advertises support for the "modern" format via ibm,client-architecture-support
|
|
hcall by setting byte 5, bit 6 of it's ibm,architecture-vec-5 option vector
|
|
structure (as described by LoPAPR v11, B.6.2.3). As with "legacy" format events,
|
|
"modern" format events are surfaced to the guest via check-exception RTAS calls,
|
|
but use a dedicated event source to signal the guest. This event source is
|
|
advertised to the guest by the addition of a "hot-plug-events" node under
|
|
"/event-sources" node of the guest's device tree using the standard format
|
|
described in LoPAPR v11, B.6.12.1.
|
|
|
|
== hotplug/unplug event structure ==
|
|
|
|
The hotplug-specific payload in QEMU is implemented as follows (with all values
|
|
encoded in big-endian format):
|
|
|
|
struct rtas_event_log_v6_hp {
|
|
#define SECTION_ID_HOTPLUG 0x4850 /* HP */
|
|
struct section_header {
|
|
uint16_t section_id; /* set to SECTION_ID_HOTPLUG */
|
|
uint16_t section_length; /* sizeof(rtas_event_log_v6_hp),
|
|
* plus the length of the DRC name
|
|
* if a DRC name identifier is
|
|
* specified for hotplug_identifier
|
|
*/
|
|
uint8_t section_version; /* version 1 */
|
|
uint8_t section_subtype; /* unused */
|
|
uint16_t creator_component_id; /* unused */
|
|
} hdr;
|
|
#define RTAS_LOG_V6_HP_TYPE_CPU 1
|
|
#define RTAS_LOG_V6_HP_TYPE_MEMORY 2
|
|
#define RTAS_LOG_V6_HP_TYPE_SLOT 3
|
|
#define RTAS_LOG_V6_HP_TYPE_PHB 4
|
|
#define RTAS_LOG_V6_HP_TYPE_PCI 5
|
|
uint8_t hotplug_type; /* type of resource/device */
|
|
#define RTAS_LOG_V6_HP_ACTION_ADD 1
|
|
#define RTAS_LOG_V6_HP_ACTION_REMOVE 2
|
|
uint8_t hotplug_action; /* action (add/remove) */
|
|
#define RTAS_LOG_V6_HP_ID_DRC_NAME 1
|
|
#define RTAS_LOG_V6_HP_ID_DRC_INDEX 2
|
|
#define RTAS_LOG_V6_HP_ID_DRC_COUNT 3
|
|
#ifdef GUEST_SUPPORTS_MODERN
|
|
#define RTAS_LOG_V6_HP_ID_DRC_COUNT_INDEXED 4
|
|
#endif
|
|
uint8_t hotplug_identifier; /* type of the resource identifier,
|
|
* which serves as the discriminator
|
|
* for the 'drc' union field below
|
|
*/
|
|
#ifdef GUEST_SUPPORTS_MODERN
|
|
uint8_t capabilities; /* capability flags, currently unused
|
|
* by QEMU
|
|
*/
|
|
#else
|
|
uint8_t reserved;
|
|
#endif
|
|
union {
|
|
uint32_t index; /* DRC index of resource to take action
|
|
* on
|
|
*/
|
|
uint32_t count; /* number of DR resources to take
|
|
* action on (guest chooses which)
|
|
*/
|
|
#ifdef GUEST_SUPPORTS_MODERN
|
|
struct {
|
|
uint32_t count; /* number of DR resources to take
|
|
* action on
|
|
*/
|
|
uint32_t index; /* DRC index of first resource to take
|
|
* action on. guest will take action
|
|
* on DRC index <index> through
|
|
* DRC index <index + count - 1> in
|
|
* sequential order
|
|
*/
|
|
} count_indexed;
|
|
#endif
|
|
char name[1]; /* string representing the name of the
|
|
* DRC to take action on
|
|
*/
|
|
} drc;
|
|
} QEMU_PACKED;
|
|
|
|
== ibm,lrdr-capacity ==
|
|
|
|
ibm,lrdr-capacity is a property in the /rtas device tree node that identifies
|
|
the dynamic reconfiguration capabilities of the guest. It consists of a triple
|
|
consisting of <phys>, <size> and <maxcpus>.
|
|
|
|
<phys>, encoded in BE format represents the maximum address in bytes and
|
|
hence the maximum memory that can be allocated to the guest.
|
|
|
|
<size>, encoded in BE format represents the size increments in which
|
|
memory can be hot-plugged to the guest.
|
|
|
|
<maxcpus>, a BE-encoded integer, represents the maximum number of
|
|
processors that the guest can have.
|
|
|
|
pseries guests use this property to note the maximum allowed CPUs for the
|
|
guest.
|
|
|
|
== ibm,dynamic-reconfiguration-memory ==
|
|
|
|
ibm,dynamic-reconfiguration-memory is a device tree node that represents
|
|
dynamically reconfigurable logical memory blocks (LMB). This node
|
|
is generated only when the guest advertises the support for it via
|
|
ibm,client-architecture-support call. Memory that is not dynamically
|
|
reconfigurable is represented by /memory nodes. The properties of this
|
|
node that are of interest to the sPAPR memory hotplug implementation
|
|
in QEMU are described here.
|
|
|
|
ibm,lmb-size
|
|
|
|
This 64bit integer defines the size of each dynamically reconfigurable LMB.
|
|
|
|
ibm,associativity-lookup-arrays
|
|
|
|
This property defines a lookup array in which the NUMA associativity
|
|
information for each LMB can be found. It is a property encoded array
|
|
that begins with an integer M, the number of associativity lists followed
|
|
by an integer N, the number of entries per associativity list and terminated
|
|
by M associativity lists each of length N integers.
|
|
|
|
This property provides the same information as given by ibm,associativity
|
|
property in a /memory node. Each assigned LMB has an index value between
|
|
0 and M-1 which is used as an index into this table to select which
|
|
associativity list to use for the LMB. This index value for each LMB
|
|
is defined in ibm,dynamic-memory property.
|
|
|
|
ibm,dynamic-memory
|
|
|
|
This property describes the dynamically reconfigurable memory. It is a
|
|
property encoded array that has an integer N, the number of LMBs followed
|
|
by N LMB list entries.
|
|
|
|
Each LMB list entry consists of the following elements:
|
|
|
|
- Logical address of the start of the LMB encoded as a 64bit integer. This
|
|
corresponds to reg property in /memory node.
|
|
- DRC index of the LMB that corresponds to ibm,my-drc-index property
|
|
in a /memory node.
|
|
- Four bytes reserved for expansion.
|
|
- Associativity list index for the LMB that is used as an index into
|
|
ibm,associativity-lookup-arrays property described earlier. This
|
|
is used to retrieve the right associativity list to be used for this
|
|
LMB.
|
|
- A 32bit flags word. The bit at bit position 0x00000008 defines whether
|
|
the LMB is assigned to the partition as of boot time.
|
|
|
|
ibm,dynamic-memory-v2
|
|
|
|
This property describes the dynamically reconfigurable memory. This is
|
|
an alternate and newer way to describe dynamically reconfigurable memory.
|
|
It is a property encoded array that has an integer N (the number of
|
|
LMB set entries) followed by N LMB set entries. There is an LMB set entry
|
|
for each sequential group of LMBs that share common attributes.
|
|
|
|
Each LMB set entry consists of the following elements:
|
|
|
|
- Number of sequential LMBs in the entry represented by a 32bit integer.
|
|
- Logical address of the first LMB in the set encoded as a 64bit integer.
|
|
- DRC index of the first LMB in the set.
|
|
- Associativity list index that is used as an index into
|
|
ibm,associativity-lookup-arrays property described earlier. This
|
|
is used to retrieve the right associativity list to be used for all
|
|
the LMBs in this set.
|
|
- A 32bit flags word that applies to all the LMBs in the set.
|
|
|
|
[1] http://thread.gmane.org/gmane.linux.ports.ppc.embedded/75350/focus=106867
|