mirror of
https://github.com/qemu/qemu.git
synced 2024-11-28 06:13:46 +08:00
docs: add sPAPR hotplug/dynamic-reconfiguration documentation
This adds a general overview of hotplug/dynamic-reconfiguration for sPAPR/pSeries guest. As specified in PAPR+ v2.7. Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com> Reviewed-by: David Gibson <david@gibson.dropbear.id.au> Signed-off-by: David Gibson <david@gibson.dropbear.id.au> Signed-off-by: Alexander Graf <agraf@suse.de>
This commit is contained in:
parent
730fce593b
commit
11eec063f2
287
docs/specs/ppc-spapr-hotplug.txt
Normal file
287
docs/specs/ppc-spapr-hotplug.txt
Normal file
@ -0,0 +1,287 @@
|
||||
= sPAPR Dynamic Reconfiguration =
|
||||
|
||||
sPAPR/"pseries" guests make use of a facility called dynamic-reconfiguration
|
||||
to handle hotplugging of dynamic "physical" resources like PCI cards, or
|
||||
"logical"/paravirtual resources like memory, CPUs, and "physical"
|
||||
host-bridges, which are generally managed by the host/hypervisor and provided
|
||||
to guests as virtualized resources. The specifics of dynamic-reconfiguration
|
||||
are documented extensively in PAPR+ v2.7, Section 13.1. This document
|
||||
provides a summary of that information as it applies to the implementation
|
||||
within QEMU.
|
||||
|
||||
== Dynamic-reconfiguration Connectors ==
|
||||
|
||||
To manage hotplug/unplug of these resources, a firmware abstraction known as
|
||||
a Dynamic Resource Connector (DRC) is used to assign a particular dynamic
|
||||
resource to the guest, and provide an interface for the guest to manage
|
||||
configuration/removal of the resource associated with it.
|
||||
|
||||
== Device-tree description of DRCs ==
|
||||
|
||||
A set of 4 Open Firmware device tree array properties are used to describe
|
||||
the name/index/power-domain/type of each DRC allocated to a guest at
|
||||
boot-time. There may be multiple sets of these arrays, rooted at different
|
||||
paths in the device tree depending on the type of resource the DRCs manage.
|
||||
|
||||
In some cases, the DRCs themselves may be provided by a dynamic resource,
|
||||
such as the DRCs managing PCI slots on a hotplugged PHB. In this case the
|
||||
arrays would be fetched as part of the device tree retrieval interfaces
|
||||
for hotplugged resources described under "Guest->Host interface".
|
||||
|
||||
The array properties are described below. Each entry/element in an array
|
||||
describes the DRC identified by the element in the corresponding position
|
||||
of ibm,drc-indexes:
|
||||
|
||||
ibm,drc-names:
|
||||
first 4-bytes: BE-encoded integer denoting the number of entries
|
||||
each entry: a NULL-terminated <name> string encoded as a byte array
|
||||
|
||||
<name> values for logical/virtual resources are defined in PAPR+ v2.7,
|
||||
Section 13.5.2.4, and basically consist of the type of the resource
|
||||
followed by a space and a numerical value that's unique across resources
|
||||
of that type.
|
||||
|
||||
<name> values for "physical" resources such as PCI or VIO devices are
|
||||
defined as being "location codes", which are the "location labels" of
|
||||
each encapsulating device, starting from the chassis down to the
|
||||
individual slot for the device, concatenated by a hyphen. This provides
|
||||
a mapping of resources to a physical location in a chassis for debugging
|
||||
purposes. For QEMU, this mapping is less important, so we assign a
|
||||
location code that conforms to naming specifications, but is simply a
|
||||
location label for the slot by itself to simplify the implementation.
|
||||
The naming convention for location labels is documented in detail in
|
||||
PAPR+ v2.7, Section 12.3.1.5, and in our case amounts to using "C<n>"
|
||||
for PCI/VIO device slots, where <n> is unique across all PCI/VIO
|
||||
device slots.
|
||||
|
||||
ibm,drc-indexes:
|
||||
first 4-bytes: BE-encoded integer denoting the number of entries
|
||||
each 4-byte entry: BE-encoded <index> integer that is unique across all DRCs
|
||||
in the machine
|
||||
|
||||
<index> is arbitrary, but in the case of QEMU we try to maintain the
|
||||
convention used to assign them to pSeries guests on pHyp:
|
||||
|
||||
bit[31:28]: integer encoding of <type>, where <type> is:
|
||||
1 for CPU resource
|
||||
2 for PHB resource
|
||||
3 for VIO resource
|
||||
4 for PCI resource
|
||||
8 for Memory resource
|
||||
bit[27:0]: integer encoding of <id>, where <id> is unique across
|
||||
all resources of specified type
|
||||
|
||||
ibm,drc-power-domains:
|
||||
first 4-bytes: BE-encoded integer denoting the number of entries
|
||||
each 4-byte entry: 32-bit, BE-encoded <index> integer that specifies the
|
||||
power domain the resource will be assigned to. In the case of QEMU
|
||||
we associated all resources with a "live insertion" domain, where the
|
||||
power is assumed to be managed automatically. The integer value for
|
||||
this domain is a special value of -1.
|
||||
|
||||
|
||||
ibm,drc-types:
|
||||
first 4-bytes: BE-encoded integer denoting the number of entries
|
||||
each entry: a NULL-terminated <type> string encoded as a byte array
|
||||
|
||||
<type> is assigned as follows:
|
||||
"CPU" for a CPU
|
||||
"PHB" for a physical host-bridge
|
||||
"SLOT" for a VIO slot
|
||||
"28" for a PCI slot
|
||||
"MEM" for memory resource
|
||||
|
||||
== Guest->Host interface to manage dynamic resources ==
|
||||
|
||||
Each DRC is given a globally unique DRC Index, and resources associated with
|
||||
a particular DRC are configured/managed by the guest via a number of RTAS
|
||||
calls which reference individual DRCs based on the DRC index. This can be
|
||||
considered the guest->host interface.
|
||||
|
||||
rtas-set-power-level:
|
||||
arg[0]: integer identifying power domain
|
||||
arg[1]: new power level for the domain, 0-100
|
||||
output[0]: status, 0 on success
|
||||
output[1]: power level after command
|
||||
|
||||
Set the power level for a specified power domain
|
||||
|
||||
rtas-get-power-level:
|
||||
arg[0]: integer identifying power domain
|
||||
output[0]: status, 0 on success
|
||||
output[1]: current power level
|
||||
|
||||
Get the power level for a specified power domain
|
||||
|
||||
rtas-set-indicator:
|
||||
arg[0]: integer identifying sensor/indicator type
|
||||
arg[1]: index of sensor, for DR-related sensors this is generally the
|
||||
DRC index
|
||||
arg[2]: desired sensor value
|
||||
output[0]: status, 0 on success
|
||||
|
||||
Set the state of an indicator or sensor. For the purpose of this document we
|
||||
focus on the indicator/sensor types associated with a DRC. The types are:
|
||||
|
||||
9001: isolation-state, controls/indicates whether a device has been made
|
||||
accessible to a guest
|
||||
|
||||
supported sensor values:
|
||||
0: isolate, device is made unaccessible by guest OS
|
||||
1: unisolate, device is made available to guest OS
|
||||
|
||||
9002: dr-indicator, controls "visual" indicator associated with device
|
||||
|
||||
supported sensor values:
|
||||
0: inactive, resource may be safely removed
|
||||
1: active, resource is in use and cannot be safely removed
|
||||
2: identify, used to visually identify slot for interactive hotplug
|
||||
3: action, in most cases, used in the same manner as identify
|
||||
|
||||
9003: allocation-state, generally only used for "logical" DR resources to
|
||||
request the allocation/deallocation of a resource prior to acquiring
|
||||
it via isolation-state->unisolate, or after releasing it via
|
||||
isolation-state->isolate, respectively. for "physical" DR (like PCI
|
||||
hotplug/unplug) the pre-allocation of the resource is implied and
|
||||
this sensor is unused.
|
||||
|
||||
supported sensor values:
|
||||
0: unusable, tell firmware/system the resource can be
|
||||
unallocated/reclaimed and added back to the system resource pool
|
||||
1: usable, request the resource be allocated/reserved for use by
|
||||
guest OS
|
||||
2: exchange, used to allocate a spare resource to use for fail-over
|
||||
in certain situations. unused in QEMU
|
||||
3: recover, used to reclaim a previously allocated resource that's
|
||||
not currently allocated to the guest OS. unused in QEMU
|
||||
|
||||
rtas-get-sensor-state:
|
||||
arg[0]: integer identifying sensor/indicator type
|
||||
arg[1]: index of sensor, for DR-related sensors this is generally the
|
||||
DRC index
|
||||
output[0]: status, 0 on success
|
||||
|
||||
Used to read an indicator or sensor value.
|
||||
|
||||
For DR-related operations, the only noteworthy sensor is dr-entity-sense,
|
||||
which has a type value of 9003, as allocation-state does in the case of
|
||||
rtas-set-indicator. The semantics/encodings of the sensor values are distinct
|
||||
however:
|
||||
|
||||
supported sensor values for dr-entity-sense (9003) sensor:
|
||||
0: empty,
|
||||
for physical resources: DRC/slot is empty
|
||||
for logical resources: unused
|
||||
1: present,
|
||||
for physical resources: DRC/slot is populated with a device/resource
|
||||
for logical resources: resource has been allocated to the DRC
|
||||
2: unusable,
|
||||
for physical resources: unused
|
||||
for logical resources: DRC has no resource allocated to it
|
||||
3: exchange,
|
||||
for physical resources: unused
|
||||
for logical resources: resource available for exchange (see
|
||||
allocation-state sensor semantics above)
|
||||
4: recovery,
|
||||
for physical resources: unused
|
||||
for logical resources: resource available for recovery (see
|
||||
allocation-state sensor semantics above)
|
||||
|
||||
rtas-ibm-configure-connector:
|
||||
arg[0]: guest physical address of 4096-byte work area buffer
|
||||
arg[1]: 0, or address of additional 4096-byte work area buffer. only non-zero
|
||||
if a prior RTAS response indicated a need for additional memory
|
||||
output[0]: status:
|
||||
0: completed transmittal of device-tree node
|
||||
1: instruct guest to prepare for next DT sibling node
|
||||
2: instruct guest to prepare for next DT child node
|
||||
3: instruct guest to prepare for next DT property
|
||||
4: instruct guest to ascend to parent DT node
|
||||
5: instruct guest to provide additional work-area buffer
|
||||
via arg[1]
|
||||
990x: instruct guest that operation took too long and to try
|
||||
again later
|
||||
|
||||
Used to fetch an OF device-tree description of the resource associated with
|
||||
a particular DRC. The DRC index is encoded in the first 4-bytes of the first
|
||||
work area buffer.
|
||||
|
||||
Work area layout, using 4-byte offsets:
|
||||
wa[0]: DRC index of the DRC to fetch device-tree nodes from
|
||||
wa[1]: 0 (hard-coded)
|
||||
wa[2]: for next-sibling/next-child response:
|
||||
wa offset of null-terminated string denoting the new node's name
|
||||
for next-property response:
|
||||
wa offset of null-terminated string denoting new property's name
|
||||
wa[3]: for next-property response (unused otherwise):
|
||||
byte-length of new property's value
|
||||
wa[4]: for next-property response (unused otherwise):
|
||||
new property's value, encoded as an OFDT-compatible byte array
|
||||
|
||||
== hotplug/unplug events ==
|
||||
|
||||
For most DR operations, the hypervisor will issue host->guest add/remove events
|
||||
using the EPOW/check-exception notification framework, where the host issues a
|
||||
check-exception interrupt, then provides an RTAS event log via an
|
||||
rtas-check-exception call issued by the guest in response. This framework is
|
||||
documented by PAPR+ v2.7, and already use in by QEMU for generating powerdown
|
||||
requests via EPOW events.
|
||||
|
||||
For DR, this framework has been extended to include hotplug events, which were
|
||||
previously unneeded due to direct manipulation of DR-related guest userspace
|
||||
tools by host-level management such as an HMC. This level of management is not
|
||||
applicable to PowerKVM, hence the reason for extending the notification
|
||||
framework to support hotplug events.
|
||||
|
||||
Note that these events are not yet formally part of the PAPR+ specification,
|
||||
but support for this format has already been implemented in DR-related
|
||||
guest tools such as powerpc-utils/librtas, as well as kernel patches that have
|
||||
been submitted to handle in-kernel processing of memory/cpu-related hotplug
|
||||
events[1], and is planned for formal inclusion is PAPR+ specification. The
|
||||
hotplug-specific payload is QEMU implemented as follows (with all values
|
||||
encoded in big-endian format):
|
||||
|
||||
struct rtas_event_log_v6_hp {
|
||||
#define SECTION_ID_HOTPLUG 0x4850 /* HP */
|
||||
struct section_header {
|
||||
uint16_t section_id; /* set to SECTION_ID_HOTPLUG */
|
||||
uint16_t section_length; /* sizeof(rtas_event_log_v6_hp),
|
||||
* plus the length of the DRC name
|
||||
* if a DRC name identifier is
|
||||
* specified for hotplug_identifier
|
||||
*/
|
||||
uint8_t section_version; /* version 1 */
|
||||
uint8_t section_subtype; /* unused */
|
||||
uint16_t creator_component_id; /* unused */
|
||||
} hdr;
|
||||
#define RTAS_LOG_V6_HP_TYPE_CPU 1
|
||||
#define RTAS_LOG_V6_HP_TYPE_MEMORY 2
|
||||
#define RTAS_LOG_V6_HP_TYPE_SLOT 3
|
||||
#define RTAS_LOG_V6_HP_TYPE_PHB 4
|
||||
#define RTAS_LOG_V6_HP_TYPE_PCI 5
|
||||
uint8_t hotplug_type; /* type of resource/device */
|
||||
#define RTAS_LOG_V6_HP_ACTION_ADD 1
|
||||
#define RTAS_LOG_V6_HP_ACTION_REMOVE 2
|
||||
uint8_t hotplug_action; /* action (add/remove) */
|
||||
#define RTAS_LOG_V6_HP_ID_DRC_NAME 1
|
||||
#define RTAS_LOG_V6_HP_ID_DRC_INDEX 2
|
||||
#define RTAS_LOG_V6_HP_ID_DRC_COUNT 3
|
||||
uint8_t hotplug_identifier; /* type of the resource identifier,
|
||||
* which serves as the discriminator
|
||||
* for the 'drc' union field below
|
||||
*/
|
||||
uint8_t reserved;
|
||||
union {
|
||||
uint32_t index; /* DRC index of resource to take action
|
||||
* on
|
||||
*/
|
||||
uint32_t count; /* number of DR resources to take
|
||||
* action on (guest chooses which)
|
||||
*/
|
||||
char name[1]; /* string representing the name of the
|
||||
* DRC to take action on
|
||||
*/
|
||||
} drc;
|
||||
} QEMU_PACKED;
|
||||
|
||||
[1] http://thread.gmane.org/gmane.linux.ports.ppc.embedded/75350/focus=106867
|
Loading…
Reference in New Issue
Block a user